Intech Instruments IN-RTB Installation Manual Download Page 1

  

 

IN-RTB  

Flow Rate and Batching Controller.

 

Installation Guide.

 

Summary of Contents for IN-RTB

Page 1: ...IN RTB Flow Rate and Batching Controller Installation Guide...

Page 2: ...p Calibration Page 7 6 1 Enter PIN Page 7 6 2 Input setup Page 7 6 3 Totaliser setup Page 9 6 4 Batching setup Page 9 6 5 Display setup Page 9 6 6 User programmable input functions Page 10 6 7 Analogu...

Page 3: ...anel cutout FLOW Flow rate Units sec units min or units hour Rate multiplier x0 0001 to x1000 TOTALISER Resolution x1 x103 x106 Features Low flow cutoff and reset at power up FEATURES Reset Reset tota...

Page 4: ...r supply HV LV Wiring Section 5 1 SECTION 4 Input Jumper Configuration Before you begin Before you can begin wiring the IF11 input module must be removed from the meter case so that the Jumpers can be...

Page 5: ...RTB C Input signal Logic NPN PNP namur TTL pushbuttons Mag Pickup Tacho D Load Sink NPN TTL pushbuttons Source PNP Namur Namur Tach Tacho Example showing a Jumper In Jumper Out SECTION 5 Wiring Before...

Page 6: ...Jumper A Input noise filtering See table in section 4 1 B Mode Counter C Input Signal Mag Pickup D Load Tach TTL input In this example the TTL logic has a separate 5V power supply Jumper A Input nois...

Page 7: ...itch on your power supply Ensure that your display is functioning before you proceed SECTION 6 Setup Calibration Enter the setup and calibration mode by pressing F1 6 1 Enter PIN A _ _ _ ENTER CAL PIN...

Page 8: ...that the controller will average Then press P Increasing the number of samples will stabilize measurement but it will also slow down response rates J _ _ _ AVE WINDOW scrolls across the bottom row an...

Page 9: ...VAL load value The batch value will be set to a user defined batching load value at power up see 6 4C C _ _ _ LOAD VALUE scrolls across the bottom row and the current batching load value appears in t...

Page 10: ...hen press P This sets the display value for cal high as at 6 7F E _ _ _ CALIBRATE ANALOG OUTPUT scrolls across the bottom row and SKIP appears in the top row If you do not wish to calibrate your analo...

Page 11: ...19200 38400 57600 or 115200 Then press P E _ _ _ PARITY scrolls across the bottom row and the current parity appears in the top row Use the and buttons to select NONE ODD or EVEN Then press P F _ _ _...

Page 12: ...across the bottom row and the current PIN default 1 appears in the top row Using the and buttons enter your new calibration PIN number Then press P to exit and return to the operational display SECTI...

Page 13: ...nt values may exceed this limitation resulting in missed output pulses G _ _ _ SP ACTIVATION scrolls across the bottom row and the last selected set point activation appears in the top row Using the a...

Page 14: ...Using the and buttons choose NONE MAKE make edge relay energises BREAK break edge relay de energises or BOTH make and break edges Then press P R _ _ _ BATCH COUNT MODIFIER scrolls across the bottom ro...

Page 15: ...efault 1 appears in the top row Using the and buttons enter your new set point entry PIN number Then press P to EXIT and return to the operational display SECTION 8 Set point Direct Access If none of...

Page 16: ...e the and buttons to adjust the brightness of the LED backlight as required and then press P The display returns to normal operating mode Appendix A Register functions A i Batching This function allow...