Lock System: Forced Sequence
Optional selection of
Forced sequence
for lock systems with 2 locks (at
least). Possibility of selecting a rigid order in which the locks of the system
open and close.
If you select option
‘Forced sequence’, users have to open lock 1 before they
can open lock 2 and only with locks 1 and 2 open, lock 3 can be opened. The
system defines that order. The user cannot change it. This function simplifies
the operation. The system is
‘partly locked’ (which corresponds to state
‘locked’ with option FS deactivated) when lock 1 has been opened. With all
locks open, the system is
‘unlocked’, not protected.
Closing order: Lock 3 closes at first, lock 2 closes thereafter and the last lock
to close is lock 1. Only after lock 1 has closed, the system is
‘locked’,
protected.
Default setting:
‘Forced sequence’ off. Activation similar to that of „Dual code“
(see above).
7.13.1.4
Lock System: Time delay
Option of setting different types of
Time delay
for locks or for persons
who have been assigned time locked periods (week programs). You can set
3 2-digit values in minutes
00<00<00
.
The first (left) value defines the opening delay, the second the release time
and the third the alarm delay or the opening delay upon alarm.
Default setting: Off. Activation similar
to that of „Dual code“ (see above).
7.13.1.5
Lock System: Time locked /
Week Programs
Option of programming 5
Week programs
. For every program you can
set two times for every week day, the time of the beginning and the ending of
a daily opening period,
Mo:08:00-17:00
, for example.
These week programs can be assigned to persons when these persons are
registered / created for the first time. Default setting: Off. Activation similar to
that of „Dual code“ (see above).