EloStar Master 3X0 / 4X0 / - smart
Operation
Manual V.1.03H
52
7.7
Operation with OTC Dependent (up to EM22)
Not evaluated by UL. Operation with dependent OTCs (single-use codes / 1x codes) is
available up to version EM22 only in case the conditions listed below are fulfilled.
Upon entering their user - / personnel number and PIN code or code - / RFID card, users
additionally enter dependent single-use code. The single-use codes are generated with
optional code generating software.
When the lock locks after having been opened via OTC, a 4-digit reply code
CIT code: XXXX
is displayed upon the operating unit This code can be passed on
via telephone, for example, and it can be used by the person in charge to end the
process.
The reply code issued most recently can also be displayed via menu
Status / Info
.
7.7.1
Conditions for OTC Dependent
•
Person registered at lock (PIN and / or card stored there)
•
Within the user matrix (TwinComm/QPadComm) the right
Single-use code
is
selected for the person
•
Activating code (7 digits) is configured
•
Date and time are correctly set and synchronous
•
The proper lock has been selected
•
Reading of access counter in code generating software and in the lock is
synchronous
•
Firmware version lower than EM22
7.8
User Groups
The users stored at the locks of every system can be divided into two groups:
The system manager activates this option via menu
„User groups“ of the display of the
operating unit.
The lock master registers PIN code for user 99.
The ex works setting regarding the group size is that group 1 contains users no. 01 to.
49 and user group 2 ranges from user no. 50 to user no. 100. Via optional software the
group size can be changed.
The lock master administers the users of the first group, user no. 99, for whom code is
to be registered and
who turns CIT master with option „User groups“ selected,
administers the users of the second group.