i-modul ISDN HIX V4
AT Command Reference
Command
Description
AT&K
Data flow control
Determines the behaviour of the data flow control of the i-modul ISDN HIX
V4 during data communication.
AT&K
No local flow control between DTE and i-modul ISDN HIX
V4 is used
AT&K3
Local flow control Hardware Handshake RTS/CTS config-
ured
AT&K4
Local flow control Software Handshake XON/XOFF config-
ured
AT#M
Received CLID
Displays the "Call Line IDentification" (CLID), which has been received with
the incoming call – this is the number of the called party at the local S0 bus
(dialled MSN).
AT*M
Transport protocol for alarm messages
AT*M0
Via data connection with the B channel protocol configured
with
ATB
AT*M1
As SMS into the D1 network (protocol TAP with X.75)
AT*M2
As SMS into the Vodafone D2 network (protocol UCP with
X.75)
AT*M3
As SMS into the E-Plus network (protocol TAP)
The SMS gateways of the GSM network providers are entered with
AT&Z1
Note:
Not valid for Socket ISDN and Pocket ISDN.
ATN
Configures transmission baud rate V.110
Configures the transmission baud rate of the i-modul ISDN HIX V4 to the
desired value. (Only valid for V.110 asynchronous B channel protocol).
ATN0
Transmission baud rate is configured automatically (equal
or less compared with the local baud rate)
ATN1
Transmission baud rate 1.200 bit/s
ATN2
Transmission baud rate 2.400 bit/s
ATN3
Transmission baud rate 4.800 bit/s
ATN4
Transmission baud rate 9.600 bit/s
ATN5
Transmission baud rate 19.200 bit/s
ATO
Returning to online mode
If the i-modul ISDN HIX V4 is in command mode after entering the escape
sequence during an existing connection,
ATO
will return the i-modul ISDN
HIX V4 back to data mode.
This command must be the last in an AT command line.
AT#O
Received CLIP
Displays the "Calling Line Identification Presentation" (CLIP), which has
been received with the incoming call – this is the number of the calling
party.
ATQ
Response suppression
Result codes and messages can be suppressed with this command.
ATQ
Replies status messages after entering a command (default)
ATQ1
No replies are output
49