insys icom i-modul ISDN HIX V4 Designer'S Manual Download Page 37

i-modul ISDN HIX V4 

ISDN Error Messages 

 

in progress at the time. This error message occurs when your waiting call is 
refused by the person you are trying to reach.  

Number changed (error code 3496) 
The phone number of the party you are calling has changed. Contact your 
telephone company for the new number. 

Destination out of order (error code 349B) 
The terminal device on the number you are calling could not be reached, because 
the port for this device did not work. Possible causes: the other party's terminal 
device is not connected or not turned on, or it is not working properly. Contact the 
other party to find out the cause. 

Invalid number format (error code 349C) 
The party you are calling could not be reached because the number you called is in 
the wrong format or incomplete. 

No circuit/channel available (error code 34A2) 
No B channel is available for a call at the moment. Upon this, the i-modul ISDN HIX 
V4 initiates a blockade release and clears a B channel with this. 

ISDN network out of order (errror code 34A6) 
Problems in the ISDN network. Wait a while and try again. 

Temporary failure (error code 34A9) 
Temporary problems in the ISDN network. You can try again immediately. 

Incompatible destination (error code 34D8) 
The terminal device of the other party is not compatible with the terminal device 
that is making the call. The call cannot be answered, therefore. This error could 
occur, for example, if the terminal device of the other party is a normal telephone. 

 

37 

 

Summary of Contents for i-modul ISDN HIX V4

Page 1: ...Designer s Guide i modul ISDN HIX V4...

Page 2: ......

Page 3: ...Inc IBM PC AT XT are registered trademarks of International Business Machine Cor poration INSYS e Mobility LSG and e Mobility PLC are registered trademarks of INSYS MICROELECTRONICS GmbH Windows is a...

Page 4: ...Automatic Call 21 6 2 1 Configuring an Automatic Call 21 6 2 2 Disabling an Automatic Call 24 6 3 Data flow control 25 6 3 1 Hardware Data Flow Control RTS CTS 25 6 3 2 Software Data Flow Control wit...

Page 5: ...t the Point To Point Connection 66 15 1 Incoming Voice Call 66 15 2 Outgoing Voice Call 66 16 Example for Handling Connections 67 16 1 Initiating and Ending an Outgoing Data Connection 67 16 2 Initiat...

Page 6: ...OS compatible 2 4 V LOW level alarm output VOL 0 4 V Input current of GND to internal VCC Typical 0 5 mA Maximum output current for state LOW IOLmax 1 6 mA Maximum output current for state HIGH IOHmax...

Page 7: ...T command set V25bis async Hotline 108 DTR SMS Sending T Mobile Vodafone E Plus I O 2 inputs 2 outputs Voice functionality yes Table 2 Technological Features 1 3 Certifications The i modul ISDN HIX V4...

Page 8: ...ht profile Item Type Description P1 SAMTEC TW series 2 row 2 mm pitch or Fischer SLY 6 81 20 Z Serial interface inputs and outputs P2 SAMTEC TW series 2 row 2 mm pitch or Fischer SLY 6 81 6 Z Phone ne...

Page 9: ...ata Terminal Ready TTL level RS232 signal 13 Output OH Off Hook 14 Output DCD Data Carrier Detect TTL level RS232 signal 15 Output RI Ring Signal TTL level RS232 signal 16 Output DSR Data Set Ready TT...

Page 10: ...Out Codec analog output max output voltage 1 575 Vpk load capacity Cmax 500 pF output current Imin 1 0 mA load resistance Rmax 1 kOhm output impedance 1 Ohm 2 Output GND OUT Ground for output 3 Input...

Page 11: ...for activation is recommended to trigger the reset safely Table 7 PIN specifications Reset input 2 5 2 Indication Signals Pin Signal Type Description 13 OH Output This output indicates Off Hook of th...

Page 12: ...Connections i modul ISDN HIX V4 2 6 Connection Example for Serial Interface Figure 4 Connection example of the serial interface 12...

Page 13: ...i modul ISDN HIX V4 Connections 2 7 Connection Example for Codec Interface Figure 5 Connection example for codec interface Figure 6 Connecting the codec interface with electret microphone 13...

Page 14: ...ers of the i modul ISDN HIX V4 exceed a certain level An application can also prompt the i modul ISDN HIX V4 via a control line to interrupt the data flow As an alternative the i modul ISDN HIX V4 can...

Page 15: ...or not An arrow will indicate prerequisites which must be fulfilled to be able to process the subsequent steps in a meaningful way You will also learn which software or which equipment you will need...

Page 16: ...le direct connection of the serial interface of the i modul ISDN HIX V4 with a typical RS232 interface of a PC overloads components of the module due to the higher voltage levels Use an RS232 level co...

Page 17: ...tep 3 mmands can be found in the chapter AT d i at all settings are stored safely and are available for the next restart 4 Configure the i modul ISDN HIX V4 using AT commands A reference of the AT co...

Page 18: ...oming connection in the same way For this the application or the PC with the terminal program must support the hardware data flow control at the serial interface otherwise the i modul ISDN HIX V4 does...

Page 19: ...ng a data connection use the escape sequence No data must be transmitted for 1 second before and after that the i modul ISDN HIX V4 changes to command mode In order to change from command mode to norm...

Page 20: ...modul ISDN HIX V4 evaluates a connection of the input to ground as alarm If no positive edge is counted at least 4 seconds after the negative edge an alarm will be processed A pause of at least 5 seco...

Page 21: ...o configure an automatic call change to the Configurator mode of the i modul ISDN HIX V4 and enter the target phone number first then select the trigger for the connection establishment and set the re...

Page 22: ...aud rate at the serial interface which is set during the automatic call use the command The automatic baud rate detection is disabled during the automatic call br n In order to view the configurable b...

Page 23: ...ry n In order to configure an idle time after which the connection is terminated if no data are transmitted use the command Replace n with a value in seconds Select n 0 to disable this function idle n...

Page 24: ...e i modul ISDN HIX V4 The serial interface speed is configured to 9600 bps 1 Perform a reset of the i modul ISDN HIX V4 2 The terminal program displays the message press CR CR ESC ESC to enter TA Conf...

Page 25: ...the CTS line to low and will thus indicate to the application to interrupt the data flow When the buffer is emptied sufficiently for the i modul ISDN HIX V4 to be able to receive data again the CTS li...

Page 26: ...end an XON character to the application This character will cause the application to send data to the i modul ISDN HIX V4 again Analogously the application can insert XON XOFF characters into the data...

Page 27: ...i modul ISDN HIX V4 1 Configure the B channel protocol X 75 at the local i modul ISDN HIX V4 using the command ATB10 2 Establish an ISDN connection to the Remote TA using the AT dialling command Use...

Page 28: ...efault setting Configuration with AT commands In order to determine a separate remote configuration number use the command AT rmsn phonenumber 6 4 3 Configuring the Remote Configuration Password You c...

Page 29: ...guration The list is empty as default setting Configuration with AT commands In order to output the phone number of a caller together with the RING message in the terminal window use the command ATV2...

Page 30: ...save the settings use the command AT W 6 5 2 Configuration at Point to Point Interface PTP Point to Point You can operate the i modul ISDN HIX V4 at a point to point interface A point to point interf...

Page 31: ...s changed by a switch command The state of the outputs can be queried in the status registers S registers S14 output 1 and S15 output 2 Both outputs are not connected to GND in default setting Configu...

Page 32: ...gurator Commands The entry is not case sensitive The TA Configurator is not active by default when operating via a terminal program Configuration with AT commands In order to use the TA Configurator u...

Page 33: ...d windows during transmission allows to detect errors and repeat the partial transmission if required 5 Byte transparent voice connection raw B channel data Byte by byte transmission without protocol...

Page 34: ...esentation This function can be used for example to acknowledge messages which are sent to a mobile phone by an application via the i modul ISDN HIX V4 The CLIP of the caller is output in the format x...

Page 35: ...mmand Resetting the device to factory default settings is performed using an AT command Configuration with AT commands In order to restart the i modul ISDN HIX V4 use the command AT RESET In order to...

Page 36: ...ched because it has no line assigned to it The phone number has the right format Enquire at your telephone company or the operator of your telephone exchange what the correct number is Normal call cle...

Page 37: ...number format error code 349C The party you are calling could not be reached because the number you called is in the wrong format or incomplete No circuit channel available error code 34A2 No B chann...

Page 38: ...equipment not supported 100B Only external equipment 1101 Wrong application ID 1102 Invalid command or message length 1103 Message queue full 1104 Message queue empty 1105 Message has been lost 1106...

Page 39: ...nnection termination before data transmis sion 3314 Fax connection termination remote termination 3315 Fax connection termination remote procedure 3316 Fax connection termination local transmitter un...

Page 40: ...3 13 78 34B7 Incoming calls barred within CUG 3 13 78 34B9 Bearer capability not authorized 3 13 78 34BA Bearer capability not presently available 3 13 78 34BF Service or option not available unspecif...

Page 41: ...patible with call state or mes sage type non existent or not implemented 3 21 78 34E3 Information element parameter non existent or not implemented 3 21 78 34E4 Invalid information element contents 3...

Page 42: ...terminal program which supports XMODEM 1k uploads like Hyperterminal Firmware update with a terminal program How to load new firmware to the i modul ISDN HIX V4 You will need a terminal program that s...

Page 43: ...ng the terminal program If you do not send a firmware file the i modul ISDN terminate the procedure after approx 60 seconds The i modul ISDN HIX V4 indicates the successful upload of the If the firmwa...

Page 44: ...e History Date Version Description 26 06 2006 1 000 New development 20 07 2006 1 001 No functional changes 12 02 2007 1 002 S register S70 implemented Command AT VMSN added CLIP number is transmitted...

Page 45: ...sion protocol for data in B channel ATB0 V 110 asynchronous e g for connections to GSM devices ATB1 V 110 synchronous ATB3 HDLC async to sync conversion PPP asynchronous single link PPP e g for intern...

Page 46: ...after switching on the messages from the i modul ISDN HIX V4 e g RING are sent with a baud rate of 115 200 bit s Autobauding works only with the data format 8N1 ATCONF Starting the INSYS ISDN TA Confi...

Page 47: ...hone number for a selected B channel connection or X 25 number for X 31 D channel subaddr Dialled sub address UUS1data Transmitted data with UUS1 signalling P Packet size xxx for X 25 connection R Rev...

Page 48: ...ory AT FL All parameters which refer to the data port are reset AT FL All parameters including ISDN protocol MSN settings and password are reset ATH Terminate connection Terminates an existing ISDN d...

Page 49: ...te Not valid for Socket ISDN and Pocket ISDN ATN Configures transmission baud rate V 110 Configures the transmission baud rate of the i modul ISDN HIX V4 to the desired value Only valid for V 110 asyn...

Page 50: ...f the S registers refer to section 1 AT S DSR Processing Configures the behaviour of the DSR control line of the i modul ISDN HIX V4 AT S i modul ISDN HIX V4 control line DSR is always ON AT S1 DSR ON...

Page 51: ...ge RINGING is dis played AT W Saves the active configuration The active configuration is saved to the non volatile memory ATX Reduced result messages Reduces the number of result messages after attemp...

Page 52: ...vice Center Number for SMS dispatch gateway x 2 Mobile phone number SMS recipient for alarm 2 x 3 Mobile phone number SMS recipient for alarm 1 Note AT Z3 nn defines the recipient number for both alar...

Page 53: ...dress 03 The value changes with configuring the B channel protocol ATBx AT K Configures layer 2 window size Sets the window size x of the layer 2 B channel protocol x 1 7 de fault 7 AT K x The default...

Page 54: ...State disconnected CdPN CgPN prev error 0 Bch Prot Async HDLC State disconnected CdPN CgPN Serial line Displays the states of the serial line signals ISDN Displays the state of the ISDN connection L1...

Page 55: ...mer default 5 s S1 Ring tone counter read only S2 Escape character default 43h S3 Return character default 0Dh S4 Line feed character default 0Ah S5 Backspace character default 1Ah S7 Waiting time for...

Page 56: ...n cmds Configure command interpreter cnr x Configure phone number dbits Data format serial defa Load default settings dhtc Configure highest 2 way channel dltc Configure lowest 2 way channel dte Confi...

Page 57: ...ts Number of stop bits sertrc Serial link trace shidle Short hold Idle data timeout shto Short hold Call timeout to abort shpa Short hold Call pause shtry Short hold Max number of connection attempts...

Page 58: ...ple subscriber number for incoming calls msni and outgoing calls msno for the data port If the number is configured to default all incoming calls are ac cepted Both values msni and msno can be display...

Page 59: ...20 asynchronous ATB20 X 31 B channel X 25 B channel option ATB21 X 31 D channel option ATB31 Multilink PPP ATB40 external IOM ATB43 external data ATB45 external audio data ATS70 Enable Codec port This...

Page 60: ...elated to the connection must use the call refer ence Default values are printed bold Command Description AT 1A Accepting an incoming call An incoming call is accepted with this command if no automati...

Page 61: ...ee party conference call is initiated with this command The B channel used with this is the one of the active connection AT 1C3PTYI cr IH cr2 Initiates a three party conference call with the call refe...

Page 62: ...an alarm request for the existing incoming call with the call reference cr AT 1RAI1 Initiates an alarm request for the existing incoming call with the call reference 1 at port 1 Table 16 Overview of t...

Page 63: ...icates that the next dialled number 9 has been received at port 1 with the call reference 1 1RINGIDOB Incoming call This response indicates an incoming call 1RINGI cr D da O oa B xx I cr Specifies the...

Page 64: ...nection request has been accepted and a ring signal has been issued at the called remote terminal 1RINGINGI cr I cr Specifies the call reference cr 1RINGINGI1 Indicates an outgoing connection at port...

Page 65: ...output of B channel data which have been received via the ISDN line via the V 24 interface Note Only possible if ATB5 is configured ATRCVDATA 0 Disables the reception of data from the ISDN line ATRCVD...

Page 66: ...are indicated by the INFO message overlapping entry If the received number is complete the application has to send a request alarm mes sage which initiates the ringing tone for the caller 1RINGI1D224...

Page 67: ...minating a connection OK OK Table 19 Sequence of initiating and ending an outgoing data connection 16 2 Initiating and Ending an Outgoing Voice Connection AT command from applica tion or via terminal...

Page 68: ...ll at i modul ISDN HIX V4 Target is dialling AT C Checking received transmission service Selecting for voice or data call 0004 0001 Voice 0002 Data 0004 3 1 kHz Audio 0010 Telephony ATB40 Selecting an...

Page 69: ...D123 Initiating an outgoing call to 123 1CRAI1B01 Connection request accepted 1RINGINGI1 Call signal to remote terminal Remote terminal accepts call 1CONNECTI1D123O234B01 Connection established AT 1CH...

Page 70: ...ication Interface Terminal Strip P1 The TTL RS232 interface should be equipped with ferrite beads directly at the module to reduce interference signals from the motherboard It is also beneficial to de...

Page 71: ...round connections of the motherboard To save costs some of the above mentioned capacitors or ferrite beads may be omitted However they should be considered in the layout to be able to integrate it wit...

Page 72: ...ut in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility 2004 108 EC and the Council Directive relating to Low Voltage 2006 95 EC as...

Page 73: ...Configurator commands 57 Table 15 Overview of the AT commands for accepting voice connections 59 Table 16 Overview of the AT commands for controlling voice connections 62 Table 17 Overview of the res...

Page 74: ...ne 25 Current configuration 50 Data connection 18 Data flow control 25 49 DCD processing 46 Default settings 35 48 Destination out of order 37 Dialling table 21 DSR processing 50 DTE address not valid...

Page 75: ...ppression 49 Result messages 51 Return character 55 RING message 29 Ring tone 18 19 Ring tone counter 55 RS232 9 S Register 55 Serial interface 12 Software data flow control 26 Standard 7 Status alarm...

Page 76: ......

Reviews: