background image

On/Off Outlet

Owner’s Manual

On/Off Outlet

Owner’s Manual

Summary of Contents for On/Off Outlet

Page 1: ...On Off Outlet Owner s Manual On Off Outlet Owner s Manual ...

Page 2: ...ched Outlet 12 INSTEON Links Understanding Linking 15 Adding to the INSTEON Hub 17 Software Only Features Beep on Button Press 19 Blink on Traffic Disable Local Programming Error Blink LED Brightness 20 Local Programming Flow Chart 23 LED Brightness 24 RF Beacon Load Sense 25 Soft Factory Reset 26 Factory Reset Factory Reset 28 Appendix Specifications 30 Troubleshooting 33 Certifications and Warni...

Page 3: ...3 Everything you need to quickly get up and running Getting Started Everything you need to quickly get up and running Getting Started ...

Page 4: ...ng for additional set button functions On Off Outlet INSTEON Wall Outlet Tools Needed for Installation Disconnect Power Phillips Screwdriver Wire Cutter Stripper Voltage Detector Flathead Screwdriver Always disconnect power before installation Contact INSTEON Support when uncertain about installation 1 866 243 8022 Lower Outlet Tamper Resistant Upper Outlet Tamper Resistant Lower Upper Status LEDs...

Page 5: ...t by tapping a set button to turn on Disconnect Power Reconnect Power Disconnect Power Reconnect Power Installation Timeline Unbox and read instructions Remove the old outlet Identify Line wire Install wall plate Connect the outlet wires to the junction box wires Carefully install the outlet into the junction box Test the outlet by tapping a set button to turn on Disconnect Power Reconnect Power D...

Page 6: ...outlet at the electrical service panel Remove the old outlet and disconnect the wires Use a voltage detector to identify the line wire Line will be energized Turn on power at the circuit breaker 1 2 4 3 ON ON ON ON ON ON ON ON ON ON ON ON Circuit Breakers Circuit Breakers Fuse Panel Fuse Panel or or 12mm 1 2 ...

Page 7: ...n the junction box Verify that the wire nuts are secure and that no exposed copper wire is visible Additional wiring diagrams can be found in the Installation Diagrams section Turn power on to the outlet at the circuit breaker panel Mount the Outlet into the junction box 5 7 6 ON ON ON ON ON ON ON ON ON ON Circuit Breakers Fuse Panel or Neutral Ground Line ...

Page 8: ...ete installation by reattaching your wall plate For the best look us an INSTEON Screwless Wall Plate Test your Outlet by tapping one of the set buttons to turn On and Off 9 8 Installation Installation of your Wall Outlet is now complete On Off ...

Page 9: ...Use the installation diagrams in this section to help you wire your Wall Outlet Installation Diagrams Use the installation diagrams in this section to help you wire your Wall Outlet Installation Diagrams ...

Page 10: ...10 Line Neutral Ground End of Run Outlet ...

Page 11: ...11 Line Neutral Ground Middle of Run Outlet ...

Page 12: ...round Ground Switched Outlet Without INSTEON Wall Switch Replacing a switched outlet requires removing the wall switch from the circuit The wall switch can be replaced by an INSTEON Wall Switch or Keypad if control is still desired ...

Page 13: ...13 Line Line Neutral Neutral Ground Ground Switched Outlet With INSTEON Wall Keypad ...

Page 14: ...recipient of control The process of associating multiple INSTEON devices to one another is called Linking INSTEON Links INSTEON devices can stand alone and function as a local switch or dimmer but their real power comes when they are connected together to form a control system Most INSTEON devices can control one another and be the recipient of control The process of associating multiple INSTEON d...

Page 15: ...Lamp Dimmer to 75 brightness A Switch B Lamp Dimmer NEW X NEW X 75 INSTEON devices that can turn other devices on or off are called controllers Sensors Switches Keypads and the Hub are common controllers NEW X INSTEON devices that receive the command of a controller are called responders Switches Keypads Plug In Modules and LED Bulbs are common responders NEW X Responders Controllers Links Remembe...

Page 16: ...lb Dimmer Switch NEW X Understanding Linking Grouping Devices Use Cross Linking You may want to group together two devices for example in a virtual three way configuration For INSTEON this is called Cross Linking To Cross Link simply turn on the devices and perform the linking process twice once in each direction To mirror Switch A and B so that they each control one another and the connected load...

Page 17: ...ping from the right side of your iOS device Navigate to All Devices from Rooms on your Android device Navigate to All Devices from Rooms on your Windows Phone device When prompted press and hold one of the set buttons on your Wall Outlet until the device beeps Your Wall Outlet is now added to your INSTEON Hub ...

Page 18: ...bled or modified using INSTEON control software such as HouseLinc and an INSTEON PowerLine Modem Software Only Features Most INSTEON devices contain features that can only be enabled disabled or modified using INSTEON control software such as HouseLinc and an INSTEON PowerLine Modem Software Only Features ...

Page 19: ...ly Features Beep on Button Press Blink on Traffic Disable Local Programming Error Blink The Wall Outlet LED will blink red once if one or more responders do not acknowledge a message and will blink green once if all responders successfully acknowledge a message By default this feature is enabled The Wall Outlet will beep every time one of its buttons are tapped By default this feature is disabled ...

Page 20: ...20 Adjust the brightness of the status LEDs from full bright to off LED Brightness Software Only Features ...

Page 21: ... to set local properties and factory reset For the best experience use software for managing device properties Local Programming Encompassing all on device programming options use the local programming to set local properties For the best experience use software for managing device properties Local Programming ...

Page 22: ...ill remain in linking mode for 4 minutes or until the device s set button is tapped This mode is very usefully for manually creating scenes Unlinking Mode Allows the removal of links from the INSTEON device The device will automatically exit unlinking mode after a link has been removed from another INSTEON device Multi Unlinking Mode Allows the removal of multiple links from the INSTEON device The...

Page 23: ...23 Flow Chart Unlinking Mode Multi Unlinking Mode Select Linking Mode Multi Linking Mode Select Press Tap Tap Press Press Press Tap Tap Exit Exit Exit Exit ...

Page 24: ...Bright Status LED Brightness Dim Linking Mode Linking Mode Press Press Press Press Bright For a bright status LED make sure the upper LED is green For a dim status LED make sure the upper LED is red Upper set button only Upper or lower set button RF Beacon Mode Tap 4x Quickly Tap Exit ...

Page 25: ...25 Load Sense Load Sense Enable Disable Enable Load Sense Linking Mode Tap 3x Quickly Disable Load Sense Linking Mode Tap 2x Quickly ...

Page 26: ...2x Quickly Press Hold Tap Reset Exit Soft Factory Reset Upper and lower set buttons A Soft Factory Reset will erase all device settings including any links made with the top and bottom outlets If On Off Outlet does not respond attempt the Alternate Factory Reset ...

Page 27: ...A factory reset will erase all links stored in the device s database as well as any customized properties Factory Reset A factory reset will erase all links stored in the device s database as well as any customized properties Factory Reset ...

Page 28: ...off power to your outlet at the electrical service panel 2 Press and hold the upper set button Alternate Procedure 3 4 Have your assistant turn power on to the outlet at the circuit breaker panel while continuing to press and hold the set button Wait for the Outlet to emit a long beep When the beep ends release the set button The switch will double beep LONG ON ON Circuit Breakers Fuse Panel or ON...

Page 29: ...29 Everything else you might need to know about your INSTEON product Appendix Everything else you might need to know about your INSTEON product Appendix ...

Page 30: ... patents UPC 813922013801 White 813922013818 Ivory 813922013825 Almond 813922013832 Light Almond 813922013849 Black 813922013856 Brown 813922013863 Grey Warranty 2 years limited Operation Local Control Yes Setup Memory Non volatile EEPROM Status LED Red Green LEDs INSTEON Features INSTEON Device Category 0x02 INSTEON Device Subcategory 0x39 INSTEON ID 1 INSTEON Links 417 INSTEON Messages Repeated ...

Page 31: ...Mechanical Beep on Button Press Yes Software configurable Beeper Yes Dimensions 4 1 H x 1 73 W x 1 6 D 104mm H x 44mm W x 40mm D Depth into Electrical Box 1 3 33mm Enclosure Material UV stabilized plastic Mounting Single or multi gang junction boxes Operating Environment Indoors Operating Humidity Range 0 90 relative humidity Operating Temperature Range 32º to 104º F 0º to 40º C Set Button Yes Sto...

Page 32: ...rge Resistance Surges over 1000 volts Power Connector NEMA 5 15R Certification FCC ID Part 15B 15C IC RSS 210 Issue 8 UL 498 Safety standard for receptacles CSA C22 2 42 Including sections 131 135 for tamper resistant outlets UL 244A CAN CSA C22 2 14 Standard for solid state controls for appliances ...

Page 33: ...ating the noise disconnect the potentially offending devices from power and test your Wall Outlet again If the issue is resolved install noise filters at each offending appliance Some small electronics devices that include an AC DC power supply can generate substantial electrical noise in some cases enough to disrupt an entire house of INSTEON devices Search your home for speaker docks small stere...

Page 34: ...werline noise may have caused the outlet to unexpectedly stop responding Try this Temporarily disconnect your outlet from power by turning power off at the electrical service panel Wait about 10 seconds and then restore power Test the outlet to see if the load will turn on or off While unusual the Wall Outlet may require a factory reset to restore normal operation Follow the procedure outlined in ...

Page 35: ...cular installation If this device does cause such interference which can be verified by turning the device off and on the user is encouraged to eliminate the interference by one or more of the following measures Re orient or relocate the receiving antenna of the device experiencing the interference Increase the distance between this device and the receiver Connect the device to an AC outlet on a c...

Page 36: ...warranties whether oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a particular purpose which may not be disclaimed or supplanted as provided above shall be limited to the two year of the express warranty above No other representation or claim of any nature...

Reviews: