Restoring Power to Open/Close Sensor 

Open/Close Sensor stores all of its settings, such as Links to other INSTEON devices, with non-volatile 

memory. Because settings are saved in this non-volatile memory, they will not be lost when the battery is 

removed. 

Resetting Open/Close Sensor to its Factory Default Settings 

The factory reset procedure can be used to clear the Open/Close Sensor memory of all INSTEON Links, 

etc.   
1)  If you are using Open/Close Sensor to control any responders, unlink them from Open/Close Sensor. 

See 

Remove Open/Close Sensor as a Controller.  

 

2)  Use a small screwdriver to gently remove the Open/Close Sensor main case 
3)  Remove the battery and wait at least 15 seconds 
4)  Press and hold Set button on Open/Close Sensor while reinstalling the battery 
5)  Release Set button when the status LED turns on 

Open/Close Sensor status LED will stay on for about 4 seconds and then turn off   

ABOUT INSTEON 

Using Dual-Band INSTEON Devices to Upgrade Your Network

 

 

What are phases? 

The majority of single-family homes in North America have two phases (or “legs”) of 110 Volts coming into 

their electricity panels. From the panel, they are distributed throughout the home, providing power to 

outlets and wall switches. These phases come together in some parts of the home to provide 220 Volts of 

power to large appliances, such as an electric oven or pool pump. 

Why do I need to bridge these phases? 

Single-band power line devices send commands via the home’s electricity, but only on a single phase. If 

the command is intended for a device on the opposite phase, there is a good chance the command will 

go unnoticed. Installing dual-band INSTEON devices, such as Access Points (#2443), on each phase will 

allow for devices to communicate between the two phases via RF. 
Dual-band INSTEON devices embody the full potential of a true INSTEON mesh  network. Taking the 

power line band signal and working in conjunction with the RF band signal, its dual-band function plays 

out in two ways: 

  Phase bridger – a receiver of commands, reacting to and translating signals sent from one power 

phase to the opposite via RF 

  Signal repeater – a participant in an INSTEON network, repeating commands intended for other 

devices whether those commands are generated from RF or power line-only devices. To ensure 

reliability, every INSTEON device confirms that it has received a command. If a Controller does 

not receive this confirmation, it will automatically retransmit the command up to five times.  

While using at least one dual-band device is required when using an RF-only device, at least two dual-

band devices are recommended in any INSTEON network to ensure reliable communication across two-

phase home wiring systems. For larger applications, it is recommended to install at least one dual-band 

device for every 750 – 1,000 square feet. 
Search for dual-band INSTEON devices at: 

www.smarthome.com/dualband 

Summary of Contents for 2421-222

Page 1: ...Open Close Sensor INSTEON Wireless Sensor Model 2843 222 2421...

Page 2: ...r a Controller 7 Remove Open Close Sensor as a Controller 7 Using Open Close Sensor s Multi Scene Mode 8 Scenes 9 Advanced Features 9 Advanced External Sensor Use 9 Restoring Power to Open Close Senso...

Page 3: ...g hidden contacts or doorbell button Key Open Close Sensor Features Installs and links to other INSTEON devices in minutes Operates via radio frequency RF to eliminate unsightly and inconvenient wiri...

Page 4: ...h other In an INSTEON network every INSTEON device also acts as a repeater receiving and sending every message to all other devices in the network So by integrating more INSTEON devices you will stren...

Page 5: ...ct Set Button Used to Link to other INSTEON devices responders Control linked responders scene 1 tap to toggle between on and off External Sensor Terminals When using an external sensor Open Close Sen...

Page 6: ...for mounting Depending on the style of your door or window frame you might need to use some double stick tape beneath one of the pieces to ensure they are at the same relative height NOTE The include...

Page 7: ...ill begin blinking You will have 4 minutes to complete the next step before linking mode automatically times out 4 Press and hold the responder Set button for 3 seconds Open Close Sensor status LED wi...

Page 8: ...ove the Open Close Sensor magnet close to the main case putting it in the closed state Open Close Sensor status LED will flash once 5 Link the desired responders for when Open Close Sensor opens scene...

Page 9: ...states opened and closed So if you have several sensors connected in the following configurations note the Open Close Sensor behavior it is assumed in this example that the Open Close Sensor internal...

Page 10: ...liances such as an electric oven or pool pump Why do I need to bridge these phases Single band power line devices send commands via the home s electricity but only on a single phase If the command is...

Page 11: ...2 This device must accept any interference including interference that may cause undesired operation of the device Le present appareil est conforme aux CNR d Industrie Canada applicables aux appareils...

Page 12: ...nties whether oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness...

Reviews: