background image

Page 1 of 26                                                                                                             Rev: 9/27/2013 4:17 PM

 

 

INSTEON

®

 Hub

 

Owner’s Manual 

2242-222 (US) 
2242-422 (EU) 
2242-442 (UK) 
2242-522 (AUS/NZ)

 

 

Summary of Contents for 2242-222

Page 1: ...Page 1 of 26 Rev 9 27 2013 4 17 PM INSTEON Hub Owner s Manual 2242 222 US 2242 422 EU 2242 442 UK 2242 522 AUS NZ ...

Page 2: ... Creation 6 Login 7 Hub Set Up 8 Using INSTEON App 9 Navigation Bar 9 Device and Sensor Status Indicators 10 Devices 11 Thermostat 14 Rooms 15 Schedules 15 Scenes 16 Troubleshooting 20 Account Troubleshooting 20 Hub Setup Troubleshooting 20 Scene Troubleshooting 21 Network Reset 21 Factory Reset 21 Specifications 23 Certification and Warranty 24 DECLARATION OF CONFORMITY 24 Certification US 25 FCC...

Page 3: ...mers x Do this all from your mobile device using a free iOS and Android Application x No monthly fees x Two year warranty Installation CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference This product is not designed or approved for use on powerlines other than 100 240VAC 50Hz or 60Hz single phase Attempting to use this product on non ...

Page 4: ... devices from any browser by visiting https connect insteon com Option 2 Use Hub with INSTEON Compatible Software Do not use this option if you are using or plan to use the Hub with the INSTEON for Hub app HouseLinc a powerful free software for managing INSTEON can be downloaded from www insteon com houselinc html 1 Install software 2 Follow software instructions for adding Hub as a computer inter...

Page 5: ...6 35mm 25 gap for proper mounting of Hub Mount Hub on Wall optional Simply screw two screws we recommend using 6 drywall screws through the marks in the drawing below leaving head of screw about from the wall and hang Hub on the screws you can then tear this sheet off ...

Page 6: ...nt 2 I already have an INSTEON Account x Select this if you have already created an existing INSTEON Hub account End User License Agreement After selecting Create New Account from the above screen you will be taken to the End User License Agreement EULA After reading tap on the text I have read and agreed to the license terms to check the box lower left corner You will automatically be taken to th...

Page 7: ...uire you to activate the account and the other will welcome you to the service If you supplied an SMS number a text message will also be sent and require you to reply with a four digit approval code When you click on the link in the email you will be taken to the http connect insteon com web page and receive a confirmation message indicating that the account has been successfully created Until you...

Page 8: ... This involves a process called port forwarding A guide to configuring port forwarding can be found under Settings House Port Forwarding Guide IP Address The static IP address you ve assigned to the Hub Assigning a static IP address can be done using your router or by specifying one here Port The port on which the Hub will listen for inbound connections Be sure to forward this port using your rout...

Page 9: ...avorites Create more rooms to make organizing your house easy Scenes Access scenes you have created Scenes are a collection of devices that respond on off 50 etc to a single command Check In Allows you to quickly check status of sensors motion open close leak smoke See Sensor Status Indicators to understand the different sensor states Temperature If you have an INSTEON thermostat the temperature w...

Page 10: ...Page 10 of 26 Rev 9 27 2013 4 17 PM Device and Sensor Status Indicators Spinning Getting status Green Device is on White Device is off sensor is OK Red Sensor is activated Yellow Status is unknown ...

Page 11: ...013 4 17 PM Devices To control a device click on its icon If you have more than nine devices use your finger to swipe to the other pages Tap All Devices to see every device in your home Tap a device icon to control that device ...

Page 12: ...tening Tap in the background area to close the popup On Off control Double tapping On or Off for dimmers will instantly turn dimmers fully on or off bypassing any programmed ramp rate and or on level Tap to increment bright dim Press and hold to bright dim until released Slide left and right to quickly adjust the light brightness dimming devices only Current status Refresh status ...

Page 13: ...lways turning on to 90 Ramp Rate Speed at which the light turns on 0 1 sec to 8 minutes LED Brightness Set the brightness of the devices local LEDs Beep on Button Press Enable this feature if you d like your device to beep when activated locally Local Programming Lock Enable this to prevent changes from being made at the device Blink on INSTEON Traffic Enable this if you d like the devices LED to ...

Page 14: ... 4 17 PM Example of the On Level and Ramp Rate adjustments Thermostat Thermostat Control Use the up and down arrows to adjust your thermostat set points Available for INSTEON devices shipped after March 2013 Dimmable devices only ...

Page 15: ...cene may be scheduled to occur at a single point of time We suggest either stagger your schedules or group all of your scheduled items into a single scene Follow the steps below to create a schedule 1 From the device or scene control page tap the settings button and select Edit This 2 Tap Schedule 3 Tap On Time and select x Time of Day followed by the time Or x Sunrise Sunset Automatically uses th...

Page 16: ...when activated from either the app a schedule or by activation from any other controller motion sensor keypad switch etc Note some older INSTEON devices may require manually tapping of the set button during scene configuration See Scene Troubleshooting for more info Add a Scene 1 From the Scene page tap Add 2 Give the new Scene a name icon and room associations 3 Tap each device that you d like to...

Page 17: ...ch scene member If a sensor was selected follow the onscreen instructions for adding them to the scene as a controller 8 When finished the app will ask if you want to turn the scene members off this may be convenient if you have created an All Lights scene and you simply want to turn off all members Controller grayed out A controller only device e g motion sensor Responder grayed out A responder o...

Page 18: ...ular device control since devices within a scene may be set to turn off when the scene is turned on activated All devices within the scene will turn off when the off button is tapped Double tapping the on button will turn all scene members full on instantly regardless of programmed scene state Tap to increment scene bright dim Press and hold to bright dim until released ...

Page 19: ... Scene name Device name Icon Device icon Room Memberships Add to rooms Schedule Set a timer for the scene Members Displays all memberships of the scene Tap on a device to edit the state or tap the trash can icon to remove from the scene ...

Page 20: ... insteon com o Make sure that the mobile device is associated to a WiFi network You may have turned off wireless network association Go to the settings section for your mobile device and allow the mobile device to connect to your local WiFi o Make sure Airplane Mode is turned off for the mobile device o Check to make sure the router is able to make an external connection If you have a computer on ...

Page 21: ...panel to adjust it to the level you want for the scene 4 Go to the physical device and tap its set button the connected light may flash 5 Tap Update Scene The scene will be updated with the older devices scene level Network Reset If you have changed your network settings and cannot connect to the Hub try performing a Network Reset 1 Press and hold INSTEON Hub set button until it beeps LED will beg...

Page 22: ...o not let go 3 While continuing to press and hold the set button re apply power to INSTEON Hub INSTEON Hub will begin to emit a long beep LED will turn red 4 After beep stops release INSTEON Hub set button After a few seconds INSTEON Hub will double beep LED will turn blue LEDs on the Ethernet jack will flash ...

Page 23: ...ge can be disabled via software Blinks red once if any responder does not acknowledge Blinks red or green during setup Blinks red to indicate traffic must be enabled via software LED brightness Adjustable from off to bright Commands supported as controller All Commands supported as responder All Software configurable Yes RF range Up to 50 meters 150 feet open air Phase bridge detect beacon Yes INS...

Page 24: ... CTL US Certifications EN 300 220 2 301 489 3 AS NZS 4268 CISPR 22 IEC 60669 2 1 FCC IC Certification and Warranty DECLARATION OF CONFORMITY Hereby INSTEON declares that this device is in compliance with the essential requirements and other relevant provisions of the following Directives 1 Low Voltage Equipment Directive 2006 95 EC 2 Electromagnetic Compatibility Directive 2004 108 EC 3 Hazardous ...

Page 25: ...his product has been thoroughly tested by Intertek ETL a nationally recognized independent third party testing laboratory The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U S and Canadian device safety standards that the manufacturing site has been audited and that the manufacturer has agreed to a progr...

Page 26: ...ession or use of this device including without limitation damage to property and to the extent permitted by law personal injury even if Seller knew or should have known of the possibility of such damages Some states do not allow limitations on how long an implied warranty lasts and or the exclusion or limitation of damages in which case the above limitations and or exclusions may not apply to you ...