Installation instructions & user guide
T210047 v1.00 March 2022 - InstaTap Commercial
SECTION 3 WARNINGS & REGULATORY INFORMATION
!
•
The InstaTap under counter boiler and under counter chiller must
be earthed, earthing is provided via the supplied power cord. The
resistance of the earth connection to each exposed metal part must be
less than 1Ω. Use the power cable supplied. It is the responsibility of the
installer to ensure the power point is earthed.
• All installation and service work must be completed by trained and
suitably qualified tradespeople. Faulty operation due to unqualified
!
persons working on this product, may void warranty coverage.
• As the installer, it is your responsibility to supply and install all valves as
required by local regulations and relevant standards.
• The InstaTap is rated for 220-240V 50Hz AC operation.
• Do not remove the cover of the under counter boiler, and under counter
chiller, without first isolating them from the power supply.
• Connect only to a potable (wholesome, cat1) mains water supply.
• Never locate the system near, or clean with water jets.
• Do not expose the InstaTap system to the elements of nature.
• A pressure limiting valve must be fitted for mains water pressures above
the max. limits stated.
• Use of tools can be hazardous, assess the risks before you start.
• A clearance envelope around the under counter appliances must be
provided to allow adequate ventilation and service access for their safe
and effective use.
• Valve and fitting threads must be sealed appropriately with PTFE tape
where compression seals are not provided.
• Do not over tighten plumbing and hose connections.
• The power cords and power outlets must be in a safe and accessible
position after installation. When positioning the under counter
FOR CONTINUED SAFETY OF THIS APPLIANCE IT
MUST BE INSTALLED, OPERATED AND MAINTAINED
IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS.