background image

 

 

The Professionals Choice

 

 

SW Series  

 

Barista Pro Counter Top Steam & Water Boiler 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

British Manufacturing 
since 1957 

 

Summary of Contents for Barista Pro SW Series

Page 1: ...The Professionals Choice SW Series Barista Pro Counter Top Steam Water Boiler British Manufacturing since 1957...

Page 2: ...release Valve p 4 5 5 0 Water and Steam Syphon Pipes p 5 6 0 Pressure switches p 5 7 0 Heating Elements p 6 8 0 Triac s p 6 9 0 Printed Circuit Boards p 6 7 10 0 The Sensing Probes p 7 11 0 Water Inle...

Page 3: ...u will require water pressure of at least 30psi 2 Bar If this is not possible a pump should be fitted Having ensured that the incoming water pressure is adequate follow these simple instructions 1 Pro...

Page 4: ...to approximately 10p s i The heating element s remain on while the inlet valve is energised maximising the products efficiency and performance characteristics The heat fill cycle continues until the l...

Page 5: ...r should be examined annually for any irregularities by a qualified person 3 0 SAFETY VALVE The boiler is fitted with a safety valve which has a set blow off pressure of 1 8 bar 25 p s i The safety va...

Page 6: ...ng screw on the switch Before adjustment release the pressure too below the required set pressure 1 The pressure switch on the left marked M or Mains orange wires is the normal operating pressure swit...

Page 7: ...triac used on the WB 2 Supreme series XE851 SW13 3kw XE854 SW13 6 6kw NOTE From Jan 2014 all 6kW units have 2 x XE851 triacs on One for each element If the triac fails in 90 of cases it will fail in...

Page 8: ...the sensing probes which acts as an insulator e g the sensor is no longer able to detect the presence of water When the Normal operating sensor black wire becomes insulated the water level will switc...

Page 9: ...ite adjustment dependant on the particular mains water pressure There have been two types of reduction valves used on this range of machines These valves must be fitted the correct way round See arrow...

Page 10: ...which if excessive can allow steam to escape through the coupling Also the spring can eventually ware or break causing the steam wand to become floppy The O ring and or the spring can be replaced by...

Page 11: ...rainer inside aerator body has been replaced the wrong way up The holes in the plastic strainer should point upwards not down 14 0 De scaling Including cleaning the level sensing probes Disconnect the...

Page 12: ...pen Not Filling Blocked inlet assembly Blocked filter in chromed water connector Water turned off Kinked inlet hose Water pressure too low or high Solenoid coil failed Scaled up top probe Top probe wi...

Page 13: ...has been detected but other sensor has not 6 The boiler has failed to fill in the allotted time Possible causes 1 The water supply is turned off 2 The inlet valve has failed 3 the water inlet hose is...

Page 14: ...36 37 LID 35 34 33 32 31 30 29 38 27 P SWITCH MOUNTING 26 BRACKET 28 25 M O 24 23 12 ALUMINIUM TRIAC PLATE 11 10 8 14 6 21 WATER 7 9 22 5 19 20 18 17 STEAM 4 13 2 3 16 15 1 D 19 Supreme 3 6...

Page 15: ...Draw off tap body Steam TP800 S 18 Grey plastic tap collar XEN303 HT 19 Water dispense arm complete DA104 A 20 Water aerator spray adaptor H FF102 H FF101 21 Draw off tap body Water TP800 22 Pressure...

Page 16: ...SA14 OUT SOL14 SA14 IN PR5 H FF113 B507 BV11 A C DESCRIPTION UPPER WATER PIPE ASSEMBLY BRAIDED BRASS 1 4 BSP ELBOW 1 2 TO 1 4 BRASS ADAPTOR NON RETURN VALVE 3 4 TO 1 2 SOLENOID OUTLET ADAPTOR SOLENOI...

Page 17: ...ANDLE ASSEMBLY TP703 TAP WASHER CHROMED TAP BODY Part Nos for Steam Arm TP800 S for Water Arm TP800 XTP1053 TAP STEM XTP802 90 TAP HANDLE V103 O RING TP702 TAP SPRING TAP BONNET HSPT100 TP 1030 TAP PI...

Page 18: ...G 254mm YELLOW WIRE PRB3 A OVER FILL PROBE ORANGE WIRE PRB4 A WATER INLET ELBOW P GAUGE REFRIGERATION FITTING P GAUGE REFRIGERATION FITTING DATA PLATE CORRECT POSITION OF BOILER TOP COVER PLATE SAFETY...

Page 19: ...N YELLOW 10 14 GREY 2 GATE RED 4 RED 5 INLET INLET BLACK 8 LIVE in from trip PCB SOLENOID TO LEDs ON FRONT PANEL ON OFF SWITCH PURPLE 19 PURPLE 20 YELLOW 21 ORANGE 22 BROWN 23 RED 24 ORANGE 15 ORANGE...

Page 20: ...REME BROWN 1 11 16 GREEN YELLOW EMPTY GATE EMPTY INLET INLET BLACK 4 VIOLET 5 LIVE in from trip PCB SOLENOID TO LEDs ON FRONT PANEL ON OFF SWITCH PURPLE 21 PURPLE 22 YELLOW 23 ORANGE 24 BROWN 25 RED 2...

Page 21: ...ME BROWN 1 11 16 GREEN YELLOW EMPTY GATE EMPTY INLET INLET BLACK 4 VIOLET 5 LIVE in from trip PCB SOLENOID TO LEDs ON FRONT PANEL ON OFF SWITCH PURPLE 21 PURPLE 22 YELLOW 23 ORANGE 24 BROWN 25 RED 26...

Page 22: ...mtr long electrical cord 3 core 4 0mm Electrical Installation Wire to a least a 30amp single phase supply via an isolation switch DRAIN OVERFLOW Not required INSTALLATION BOILER RATING SPECIFICATION 5...

Reviews: