![Inspur 3408 Series Configuration Manual Download Page 16](http://html.mh-extra.com/html/inspur/3408-series/3408-series_configuration-manual_2069375016.webp)
11
Fast RAID initialization
Background data consistency check
Drive background media patrol and repairing
Compliance with the Disk Data Format (DDF) specification
Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T)
Global and dedicated hot spare (HS) drives
Auto rebuild from HS drives
Emergency HS drives
SES, SGPIO, and peripheral management
32 physical drives (PDs) with a maximum capacity of 64 T per drive
Power save mode of drives
Connection to extended devices, up to 32 drives on an Inspur server
The following table lists the drive number limits and redundancies of different RAID
levels of Inspur SAS3408iMR RAID controller card.
Table 2-1 Drive Number Limits and Redundancies of Different RAID Levels
RAID Level
Number of Drives Supported
Number of Drive
Redundancies
RAID 0
1 - 32
0
RAID 1
2 - 32
Number of drives/2
RAID 5
3 - 32
1
RAID 10
4 - 32
Number of spans
RAID 50
6 - 32 (2 - 8 for RAID 5)
Number of spans
Note:
The failed drives cannot be adjacent
A maximum of 1 failed drive is allowed in each span of RAID 10 and RAID 50.
2.3
About Inspur SAS3508MR
Inspur SAS3508MR is specially designed to provide highly reliable external storage
and expansion capabilities for servers. Refer to the figure below for its appearance.
Summary of Contents for 3408 Series
Page 62: ...57 Figure 3 52 Selecting the Drive to be Configured Figure 3 53 Operation Screen ...
Page 78: ...73 Figure 3 73 Setting Choose Profile to 13_PD64 NVMe4 ...
Page 85: ...80 Figure 4 8 Selecting Load Driver 11 On the screen shown click Browse and press Enter ...
Page 86: ...81 Figure 4 9 Clicking Browse To install the driver 1 Select GHOST C as shown below ...
Page 89: ...84 Figure 4 12 Loading the Driver 4 On the screen shown click Next ...