INSTALLATION INSTRUCTIONS
Electrical connections
An individual branch (or separate) circuit serving only your dryer is recommended.
DO NOT USE AN EXTENSION CORD.
Gas models - U.S. and Canada
A 120-volt, 60Hz AC approved electrical service, with a 15 ampere fuse or circuit
breaker is required.
Electric models - U.S. only
The dryers require a 120/240 volt, 60 Hz AC approved electrical service. The
electric service requirements can be found on the data label located behind the
door. A 30-ampere fuse or circuit breaker on both sides of the line is required.
• If you use a power cord, you should plug the cord into a 30-ampere receptacle.
• A power cord is NOT provided with U.S. electric model dryers.
Electric models - Canada only
You need a 120/240 volt, 60Hz AC approved electrical service fused through a
30-ampere fuse or circuit breaker on both sides of the line.
All Canadian models are shipped with the power cord attached. The power cord
should be plugged into a 30-ampere receptacle.
Power outlet types
WARNING: RISK OF ELECTRIC SHOCK
When local codes allow, the electrical supply of your dryer may be connected
by means of a new power supply cord kit, marked for use with a dryer, that is UL
listed and rated at a minimum of 120/240 volts, 30-ampere with three No. 10
copper wire conductors terminated with closed loop terminals, open-end
spade lugs with turned up ends, or with tinned leads.
• Do not reuse a power supply cord from an old dryer. The power cord electric
supply wiring must be retained at the dryer cabinet with a suitable UL-listed
strain relief.
• Grounding through the neutral conductor is prohibited for (1) new
branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and
(4) areas where local codes prohibit grounding through the neutral
conductor. (Use a four-prong plug for four-wire receptacles, NEMA type
14-30R.)
Three-wire outlet (10-30R)
Four-wire outlet (14-30R)