background image

 

www.insigniashowers.com

 

Last Modified 17/05/2021

 

 12 

ST16 x12

 

Step 5 —

 

Connecting the back panels

 

 

DO NOT SCREW BACK PANELS TO THE 

TRAY. 

 

PRESS PANELS 

DOWN FIRMLY 

ON TO THE 

RUBBERGUM.

 

Summary of Contents for 1000

Page 1: ...upport Call 01908 317512 and request technical support for aiding your installation Replacements Parts Inside of your warranty period visit https www insigniashowers com click support and make a warranty claim Spares Replacements Parts Outside of your warranty period visit https www insigniashowers com replacement parts html WARRANTY REG NO _______________________ To claim your full 2 year warrant...

Page 2: ...ing RubberGum 11 Installing the Back Panels 12 Installing the Column 13 Installing the Fixed Glass Panels 14 Installing the Glass Seals 15 Installing the Roof 16 Installing the Door Wheels 17 Installing the Accessories 18 Water Valve Connections 19 Control Panel Connections 20 Steam Generator Connections 21 Signing off your shower 22 Control Panel Operating Instructions 23 Spare Parts List 26 Stea...

Page 3: ...ur easy to follow Installation videos live online NOW to make your installation process easier than ever before Simply click the link below and watch the installation process Please note this build video is for an Insignia Platinum Shower however 90 of the process is the same for assembly so it should help you on your way Shower Install ...

Page 4: ...d this booklet with great care to ensure you get the best out of your build and have a shower that will last for many years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish ...

Page 5: ...e build up may cause damage to your shower and will not be covered under warranty TIP 3 Installation These showers are designed to be free standing and movable from their location should you have the need to replace anything ALWAYS USE Flexible braided water inlet pipes not supplied and not central heating plastic type Get your WRAS Approved Flexible Braided Hoses here www insigniashowers com wras...

Page 6: ...www insigniashowers com Last Modified 17 05 2021 06 ...

Page 7: ...alves not supplied 2x Braided hoses not supplied Steam version requires 3 If you haven t purchased these already simply click the following link below or copy in to any web browser For ease we have listed the required pack below for your install Shower cabins require pack 1 Shower cabins with steam require pack 2 https www insigniashowers com wras approved braided hoses html Parts Required STEAM V...

Page 8: ... 4 8 ST10 10mm Screws 8 ST16 16mm Screws 28 ST20 or WN20 20mm Nut and Bolt or Wing Nut 12 AMI01 Jubilee Clip For steam version only 1 SW9 Small Washers 20 DB9 Drill Piece 1 Framework Top Rail Bottom Rail Outer Fixed Uprights Inner upright posts Magnetic door seals Rear flap door seals Framework Securing Clips 1 1 2 2 2 2 4 Roof Roof with fittings 1 VERY IMPORTANT Have you got everything If not ple...

Page 9: ...howers com Last Modified 17 05 2021 09 Twist to adjust Step 1 Level the Tray and connecting the waste NOTE FOR STEAM SHOWERS ONLY Check the Spigot is drilled out prior to fitting If it isn t ensure you drill it out ...

Page 10: ...www insigniashowers com Last Modified 17 05 2021 10 Step 2 Connecting framework Wider rail on top Narrow rail at the bottom 1 2 3 Internal View Framework securing clips x4 ...

Page 11: ...showers com Last Modified 17 05 2021 11 Step 3 RubberGum the tray Apply RubberGum to raised sections of the tray and remove backing paper Step 4 Fix framework to the tray PRESS FRAME DOWN FIRMLY ONTO THE RUBBERGUM ...

Page 12: ...www insigniashowers com Last Modified 17 05 2021 12 ST16 x12 Step 5 Connecting the back panels DO NOT SCREW BACK PANELS TO THE TRAY PRESS PANELS DOWN FIRMLY ON TO THE RUBBERGUM ...

Page 13: ...Last Modified 17 05 2021 13 Step 6 Column Connection NOTE Column features varies between models Rear View attach nuts and bolts or wing nuts from rear Below diagram shows the nut bolt install SW9 x 12 ST20 x 12 or WN20 x 12 or ...

Page 14: ...www insigniashowers com Last Modified 17 05 2021 14 Step 7 Fixed Glass Connection Slide glass in Attach Upright Use outer hole x Internal View x x Repeat process for other side ST16 x 2 ...

Page 15: ...d 17 05 2021 15 Step 8 Fitting the glass seals Fit seal inside the shower between the glass and framework Step 9 Fitting the door stops Internal View Top Rail Internal View Bottom Rail ST10 x8 SP072 x8 2x 7mm Seals 12mm 7mm 2x 12mm Seals ...

Page 16: ...www insigniashowers com Last Modified 17 05 2021 16 Step 10 Attaching the Roof ST16 x6 Screw from the rear Step 11 Fit door handles seals and magnets ...

Page 17: ...dified 17 05 2021 17 Step 12 Fit top door wheels x 4 Slide cover off Door Tighten to secure wheels into door runners DO NOT OVERTIGHTEN Step 13 Fit bottom door wheels x 4 Slide cover off Door Step 14 Fitting the doors Slide covers on ...

Page 18: ...www insigniashowers com Last Modified 17 05 2021 18 Step 15 Accessory Installation Slide cover off Slide cover off ...

Page 19: ...iashowers com Last Modified 17 05 2021 19 Monsoon Head Jets Cold Water Inlet Hot Water Inlet Outlet for Steam version only Step 16 Valve Water Connections Hand Shower 2 x Washers located on the back of the valve ...

Page 20: ...www insigniashowers com Last Modified 17 05 2021 20 Step 17 Control Panel Connections Power Supply Antenna Speaker Speaker Roof Light Premium Steam Version Premium Version ...

Page 21: ...all a static water line from the shower valve middle feed to the steam generator Even with a static water line flexible hosing will still be required for the hot and cold water feeds If you choose this option please ensure you purchase the correct hose pack from www insigniashowers com 3 Drain Connect the grey rubber hose from the steam generators drain opening to the nozzle on the shower waste as...

Page 22: ...not aim the hand shower directly at the joints of your shower as this does not fall under normal showering conditions However due to Insignia s unique design of the shower tray water will only leak back in to the tray so you won t get flooded 4 Visually check the water flow in to the waste and adjust the feet of the tray accordingly to ensure the direction of the water flows towards to the waste t...

Page 23: ...accidentally activated Other buttons will remain functional whilst in this state of lock mode Button 5 Music Press once for FM Radio and press twice for Bluetooth For tuning radio stations or connecting Bluetooth please see the next page For volume control once on the radio or Bluetooth setting press Mode button 3 then use the left and right arrows to change the volume The volume is denoted by a n...

Page 24: ... Step 1 To tune your radio channels firstly press the music function button which looks like a musical note Tuning your radio channels Step 1 To connect a device via Bluetooth press the music function button twice which looks like a musical note the control panel will then show INS Step 2 Then once the radio is on press and hold the mode button until it starts scrolling Step 3 Finally once the pan...

Page 25: ...n 3 7 Audio Volume Press up or down to increase or decrease the volume in the cabin Also use this when manually searching for a radio station Button 4 5 Skip button Press to skip radio station on the radio setting When the Bluetooth is activated this will skip to the next song in your playlist Button 6 Lights Press to activate or deactivate the lights Button 8 Power Button On Off 3 To see our tuto...

Page 26: ...riser bar Shower holder for riser bar Water Inlet bottom part of riser bar SP142 Shower waste SP097 Chrome rectangular door handles SP190 Glass Shelf SP196 Thermo sensor holder steam version only SP072 Door stoppers SP276 Twin Door Wheels Non Push SP276A Twin Door Wheels Push Button SP205 Chrome Steam Outlet steam version only SP105 Chrome Flexible Hose SP243a Fold down seat SP036 Speaker SP085 Sp...

Page 27: ...ore use 8 If you have any underlying health conditions which you feel could be aggravated by using a steam room consult your GP before use 9 If you begin to have any issues with your health after using a steam room stop immediately and consult your GP regarding your symptoms before continuing to use 10 Consult your GP before using the steam room if you re on medication at all especially with drows...

Page 28: ... see a small C to the right of the display The large number in the middle of the display can be changed by pressing the arrows 4 The maximum temperature you can reach is 60 C The average temperature in a steam room is approximately 38 C 4 To set the length you wish the steam to run for press the function button again 3 then use the arrows 4 to set your desired time The maximum length that can be s...

Page 29: ...www insigniashowers com Last Modified 17 05 2021 29 Bathroom Electrical Zones ...

Page 30: ...hroom goes past zones 0 1 and 2 portable electrical appliances can be utilised if their cord length doesn t allow them to be used in zone 2 For example a hairdryer can be used in the outside zones provided its extended length doesn t enable it to be used in zone 2 Despite the fact that installing electrical appliances past zone 2 is allowed without an IP number it is recommended that electrical ap...

Page 31: ...common crossed out wheelie bin label We accept returns of all products carrying the Insignia brand All other products are either considered outside the scope of WEEE or Insignia is not technically the producer of these products Insignia also accepts historic like for like WEEE returns All WEEE returned to Insignia will be recycled in appropriate treatment and recycling centres in accordance with t...

Page 32: ...www insigniashowers com Last Modified 17 05 2021 32 ...

Reviews: