background image

 

 

 

 

 

 

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS 

 

 

HELICOIDAL PUMP 

 

KIBER KTE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual Original 

 

01.624.30.01EN 

 

(0) 2021/05

0

1

.6

2

4

.3

2

.0

0

2

3

 

Summary of Contents for KIBER KTE

Page 1: ...INSTALLATION SERVICE AND MAINTENANCE INSTRUCTIONS HELICOIDAL PUMP KIBER KTE Manual Original 01 624 30 01EN 0 2021 05 01 624 32 0023...

Page 2: ...BER KTE 100 From serial number IXXXXXX to IXXXXXX 1 XXXXXXXXXIIN to XXXXXXXXXIIN 1 Fulfills all the relevant provisions of the following directive Machinery Directive 2006 42 EC Machinery Safety Direc...

Page 3: ...7 5 3 Transport and storage 8 5 4 Location 8 5 5 Pipes 9 5 6 Electrical installation 9 5 7 Level sensor 10 6 Start up 6 1 Checks before starting the pump 11 6 2 Checks when starting the pump 11 7 Trou...

Page 4: ...ctions failure of specific maintenance and repair procedures possible electrical mechanical and chemical hazards risk to the environment due to the type of substances released 2 3 WARRANTY The conditi...

Page 5: ...lues be exceeded NEVER touch the pump or the pipework during operation if the pump is being used for transferring hot liquids or during cleaning The pump contains moving parts Never place your fingers...

Page 6: ...in suspension The most significant build details of this type of pump are as follows pump mounted on a trolley stainless steel hopper with drain level sensor or product detector And optionally switch...

Page 7: ...uctions manual instructions and service manual of the motor1 Unpack the pump and check the following The suction and discharge connections of the pump removing any rest of packaging materials The pump...

Page 8: ...ould fall down and cause damages to the operators Make sure that the pump is properly supported 5 4 LOCATION Place the pump as close as possible to the suction tank and it is possible below the level...

Page 9: ...der to avoid vibrations and stress on the pump 5 5 1 Shut off valves The pump may be isolated for maintenance To accomplish this shut off valves must be installed and connected to the pump s suction a...

Page 10: ...30 01EN 0 2021 05 5 7 LEVEL SENSOR The level sensor of the KTE pump is resistive type Mount the level sensor as indicated in the next figure to sure the good functioning of the pump M nimum level dim...

Page 11: ...ting indicated on the motor plate Check that the direction of rotation of motor is the right one 6 2 CHECKS WHEN STARTING THE PUMP Check that the pump is not making any strange noises Control the disc...

Page 12: ...ed pump Abnormal wear Leaking through the packing material PROBABLE CAUSES SOLUTIONS Wrong direction of rotation Reverse the motor rotation direction Lack of product Fill the hopper Pump speed too hig...

Page 13: ...double lip seals of the obturation following the instructions in the chapter 8 8 Disassembly and assembly of the pump 8 3 MAINTENANCE OF THE SEALS SEALS REPLACEMENT Preventive maintenance Replace aft...

Page 14: ...sary to disassemble the pump If the automatic cleaning process is not provided proceed to disassemble the pump as indicated in the chapter 8 8 Disassembly and assembly of the pump Check the concentrat...

Page 15: ...their washers 53G 5 Remove the protector of the motor 47 loosening the screws 52F with their washers 53F 6 In models KTE 60 KTE 80 and KTE 90 separate the gear motor 93 removing the nuts 54 and the w...

Page 16: ...the washers 53G 9 Introduce the stator 22 10 Place the discharge nozzle 34 tightening the nuts 54A and the washers 53A 8 8 3 Disassembly of the obturation 1 Perform steps 4 to 10 of chapter 8 8 1 Dis...

Page 17: ...eration area exceeds 85 dB A Pump type Caudal m3 h Speed rpm Power kW KTE 60 10 12 200 3 KTE 80 20 25 200 5 5 KTE 90 30 40 200 7 5 KTE 100 45 55 200 9 2 Materials Parts in contact with the product 1 4...

Page 18: ...Technical Specifications 18 INOXPA S A U 01 624 30 01EN 0 2021 05 9 2 EXPLODED DRAWING TECHNICAL SECTION AND PARTS LIST 01 624 32 0013...

Page 19: ...Technical Specifications INOXPA S A U 01 624 30 01EN 0 2021 05 19 01 624 32 0020 01 624 32 0024 Detail A Detail A...

Page 20: ...al screw 16 A2 52A Hexagonal screw 5 A2 52B Hexagonal screw 4 A2 52C Hexagonal screw 4 A2 52D Hexagonal screw 4 A2 52E Hexagonal screw 1 A2 52F Hexagonal screw 4 A2 52G Hexagonal screw 2 A2 53 Washer...

Page 21: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Page 22: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Page 23: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Page 24: ...Banyoles Spain Tel 972 575 200 Fax 34 972 575 502 How to contact INOXPA S A U contact details for all countries are continually updated on our website Please visit www inoxpa com to access the informa...

Reviews: