5.5. ELECTRICAL INSTALLATION
Before connecting the electrical motor to the mains, check local regulations on electrical safety as well as the
applicable standards.
Check the instructions manual of the manufacturer of the motor for information on how to connect it to the mains.
Take the connection of the electrical motors must be performed by qualified personnel.
Take the appropriate measures to prevent any fault.
The motor must be provided with devices for protection against power overload and short-circuits.
The agitator cannot be used in areas where there is a risk of fire or explosion when this has not been
specified in the order.
5.6. ASSEMBLY
To locate and fix the agitator in the support flange of the tank, the propeller must be removed from the shaft. Once
the base of the agitator is placed on the supporting flange, the fixing nuts and screws will be assembled in their
corresponding holes, without being tightened. When this operation has been carried out, the agitator must be
levelled using the following method:
1. Place a spirit level against the shaft.
2. Check 4 points at 90º to each other around the circumference of the shaft and at the same height.
3. Once the shaft is level, firmly tighten the fixing nuts and screws. Finally, the propeller is mounted on the
end of the shaft. Be careful when assembling the shaft not to hit or strain it to avoid it being bent.
Force should never be applied to the end of the agitator shaft, as it can easily suffer permanent
damage.
Check the alignment of the agitator shaft with the half shaft once its assembly is completed.
ATTENTION
ATTENTION