Inovonics Frequency Agile FA210 Installation Manual Download Page 1

 

 

FA210 / FA210W / FA210M 

Frequency Agile

®

 900MHz 

Reduced-size 

Universal transmitter 

 

 

Mounting the FA210 

Reduced-size universal transmitter 

 

FA210 Programming 

1. 

Connect cable from programming 
device to programming header on 
transmitter. 

2. 

Press Reset button on transmitter. 

3. Disconnect 

cable. 

 

 
 
 
 
 

Technical Support 

Phone 800.782.2709 

 

Inovonics Wireless Corporation 

315 CTC Blvd 

Louisville CO 80027 

 

www.inovonics.com

  

 
 

LIT-FA210-INSTALL 03396C.DOC 

11-Jan-06

 

1. 

Mount the bracket on the 
wall with the screws 
provided. Screw heads 
must be flush or slightly 
recessed. (A #8 drywall 
screw can also be 
used.) 

2. 

Clip the transmitter onto 
the bracket. Hook the 
bottom catch first, then 
press the top into place. 

 

FA210M 

Instant Response Transmitter 

 

The FA210M provides an instant response to a 
momentary closure on the input terminals. A 
1.5 second closure is not required as with the 
standard FA210. 

The transmitter will only operate properly when 
programmed as a normally open input device. End of 
Line Resistor and Internal Contacts are not 
supported. 

3. 

The housing may be secured to the bracket 
with a third mounting screw, located 
beneath the battery. Accessing this screw 
on an active transmitter requires opening 
the housing and removing the battery, 
causing a tamper condition (if monitored). 

4. 

To dismount the FA210, pull the transmitter 
housing carefully out of the mounting 
bracket from the top. 

5. 

An EOL resistor is shipped with the 
transmitter for optional tamper resistance.  
If desired, attach the EOL resistor.

 

NOTE: FA210, FA210W and FA210M transmitters 

do not require reprogramming after loss of 
power
 They retain programming data in non-
volatile memory. Install new battery and 
press reset button
 to re-initialize the 
transmitter  

 

Receiver Programming: The FA116 programmer must be used 
to enable the internal contact feature when programming the 
FA210/FA210W to FA464DR or FA416 receivers. The FA210W 
“widegap” feature cannot be used on FA404 or FA401 receivers. 

An alarm transmission is caused by providing a 
momentary switch closure to the input. Typical 
required time is 10 milliseconds, but during the 
battery test (every 18 hours) the required closure time 
can be as long as 100 ms. In life-safety applications 
the 100 ms spec should be followed. 

To conserve battery life, the momentary closure 
should not be greater than 4.0 seconds. 

©

 Inovonics Wireless Corporation 2001 

Specifications 

 

 

External contacts: 

N/O or N/C  

 

Wire gauge: 

14-22 AWG 

 Distance, external switch to FA210(W): 

10 feet , maximum 

 

Minimum contact closure duration: 

1.5 seconds 

 Internal 

contacts 

(FA210W only): 

as needed 

 

EOL(FA210, FA210W only):: 

as needed 

 

Typical battery life: 

4 years 

 

Battery (BAT604): 

3.0V Panasonic CR123A (or
approved equivalent) 

 

Battery part #: 

BAT604 

 

Operating environment: 

32 to 140°F (0 to 60°C) 

 

 

The FA210W has 2 internal contact magnetic reed switches. The 
switches are located to permit either horizontal or vertical 
mounting of the FA210W unit. The FA210W can monitor internal 
and external contacts at the same time. Maximum operating gap 
for the FA210W is 5/8".

 

NOTE: Inovonics products are intended to be 
installed by professional security technicians.

 