EN1248 Glassbreak Detector

Installation and Operation Manual

1 Overview

The EN1248 glassbreak detector is a wireless omni-directional glassbreak 

detector, providing detection coverage of 180°, as measured from the 

sensor to the point on the glass farthest from the sensor.

1.1 Inovonics Contact Information

If you have any problems with this procedure, contact Inovonics technical 

support:

• E-mail: [email protected].
• Phone: (800) 782-2709; (303) 939-9336.

2 Installation and Startup

2.1 Installation Notes

• These products are designed to be maintained by professional 

security technicians

• Products are tested for indoor use
• All products should be manually tested weekly

2.2 Install the Battery

Before installing the EN1248 glassbreak transmitter you will need to install 

the battery. To install the battery:

1.

Use a Phillips screwdriver to loosen the housing screw.

2.

Tilt out the glassbreak detector to remove it from the base.

 Figure 1  

Remove the glassbreak detector from the base

3.

Install the batteries.

 Figure 2  

Install the batteries

2.3 Register the Transmitter

EN1248 transmitters must be registered. Refer to receiver, network 

coordinator or control panel installation instructions to register the EN1248 

transmitter. 

1.

When prompted to register the device, remove and reinstall the 

batteries.

Caution: 

The EN1248 should be tested after registration to ensure 

operation. To test the EN1248, activate each of the conditions and ensure 

an appropriate response.

2.4 Mount the EN1248

1.

Choose your mounting location, considering the following:

• Coverage is measured from the detector to the point on the glass 

farthest from the detector.

• The detector can be mounted as close as 3.28’ (1m) from the glass.
• Mounted on the opposite or adjoining walls, the maximum range is 

26.2’ (8m) for plate or glass.

• Mounted on the ceiling, the maximum range is 19.6’ (6m) for plate, 

tempered, laminated and wired glass.

• For armor-coated glass, mount sensor no more than 11.9’ (3.65m) 

from glass.

2.

Use the included three mounting screws to mount the EN1248 to the 

wall.

 Figure 3  

Mount the glassbreak detector

For product and installation videos visit us at 

www.inovonics.com/videos or use the QR 

code below.