background image

6/7/12 05043G © Inovonics, 2012 - www.inovonics.com

EN1215WEOL EchoStream® Universal 
Transmitter with Wall Tamper

Installation Instructions

1 Overview

The Inovonics EN1215WEOL wide gap universal transmitter with an 
included wall tamper switch has a built-in magnetic reed switch on the 
side, with a magnet that supports a 5/8" inch gap. The magnetic reed 
switch can be used with both ferrous and non-ferrous material. A 2.2K 
ohm end of line resistor is included with the EN1215WEOL, and is 
required for operation.

The EN1215WEOL includes a back tamper switch. The tamper condition 
must be defined within the control panel as a trouble condion when the 
system is disarmed, and as an alarm condition when the system is armed.

Note: 

For UL installations, refer to the 

EN4216MR Installation and 

Operation Manual

, the 

EN4232MR Installation and Operation Manual

, or 

the 

EN7285 Installation Instructions

. The switch contact must also be 

located in the same room as the EN1215WEOL, and the EN1215WEOL 
must be installed in accordance with UL 681 and ULc S302.

Note: 

The cable length from the switch contact must not to exceed 10 

feet.

Caution: 

The EN1215WEOL contains both a wired input and an input 

activated by a reed switch and magnet. The reed switch and magnet 

MUST

 be used unless the application (control panel) specifically supports 

both inputs as separate devices. Use of the wired input is optional.

1.1 Inovonics Wireless Contact Information

If you have any problems with this procedure, contact Inovonics technical 
services:

E-mail: [email protected]

Phone: (800) 782-2709

1.2 EN1215WEOL External Components

 Figure 1  

EN1215WEOL external components

1.3 EN1215WEOL Internal Components

 Figure 2  

EN1215WEOL internal components

1.4 What’s In The Carton

Wall mount screws

Wall mount anchors

Selection jumpers

3.0V lithium battery

Housing closure screw

Magnet

2.2K ohm end of line resistor 

2 Installation and Startup

2.1 Installation Notes

These products are designed to be installed and maintained by 
professional security technicians.

Products are intended for indoor use.

Manually test all products weekly.

2.2 Initial Setup

Battery Installation
1.

Insert a small screwdriver to depress the housing release tab on the 
bottom of the transmitter; pry the housing apart.

 Figure 3  

Open the EN1215WEOL Housing

2.

Install the new battery.

3.

Press the 

Reset

 button to initialize the transmitter.

4.

Test the transmitter and ensure appropriate response.

Select the Frequency Band

EchoStream products are able to use a range of radio frequencies, and 
must be configured for your geographic area. This product ships with a 
default frequency range of 902-928 MHz for use in North America. If you 
are using the product in North America, skip to step 7; if you are using the 
product in Australia or New Zealand, you will need to configure the 
transmitter.

5.

Place a selection jumper on the appropriate frequency band selection 
pins.

Place the jumper on the right two pins, marked NZ, to set the 
frequency range to 921-928 MHz for New Zealand.

Place the jumper on the left two pins, marked AU, to set the 
frequency range to 915-928 MHz for Australia.

Note: 

Only devices set for use in North America are configured for UL 

installations.

6.

Press the 

Reset

 button to complete configuration.

Caution: 

When pressing the 

Reset

 button, make sure you don’t also 

touch the frequency band selection pins. Touching the frequency band 
selection pins while pressing the 

Reset

 button can inadvertently set the 

EN1215WEOL to the wrong frequency band.

Select Input Type and Wire Resistor

The N/O-N/C selection pins allow the choice of a normally open or 
normally closed state for the contact circuit wired to the input terminal.

The transmitter is shipped set for normally open, with a selection jumper 
on the N/O selections pins.

Set for normally open operation:

7.

Place a selection jumper on the selection pins to select normally 
open.

8.

Use 22 AWG wire to wire the 2.2K ohm resistor in parallel with the N/0 
contact per Figure 4. The distance from the external contact to the 
EN1215WEOL must not exceed 10 feet (3 meters).

9.

Press the 

Reset

 button to complete configuration.

 Figure 4  

Wired for N/O operation

Set for normally closed operation:

10.

Remove the selection jumper from the selection pins. 

11.

Use 22 AWG wire to wire the 2.2K ohm resistor in series with the N/C 
contact per Figure 5. The distance from the external contact to the 
EN1215WEOL must not exceed 10 feet (3 meters).

12.

Press the 

Reset

 button.

 Figure 5  

Wired for N/C operation

A

Housing closure screw hole

B

Wall tamper switch

A

B

A

Housing tamper button

B

N/O - N/C jumper

C

Input terminal

D

Reset button

E

Wall-mount screw holes

F

Housing closure screw hole

G

Reed switch

H

Frequency band selection pins

A

B

C

D

E

E

F

G

H