- 68 -
4 Operation Panel
4
4.2 Display of the Operation Panel
●
Transition relation between the operation panel display and the host controller operation object
The following mapping relation exists between the function code (decimal) for the panel display and the
operation object dictionary of the host controller (hexadecimal, "Index" and "Sub-index"), and should be
noted in use:
Object dictionary index = 0 x 2000 + function code group No.;
Object dictionary sub-index = hexadecimal of offset in function code group + 1, for example:
Operation Panel Display
Object Dictionary Operated by the Host Controller
H00-00
2000-01h
H00-01
2000-02h
……
……
H01-09
2001-0Ah
H01-10
2001-0Bh
……
……
H02-15
2002-10h
Note
The following section describes content displayed on the operation panel side (decimal) about
operation panel display and parameter setting. The parameters are different from the those
viewed on the host controller background (hexadecimal). Please make the conversion by
referring to the above table when needed.
●
The operation panel can display the running state, parameter, faults, and monitored information Run
settings of the servo drive.
State display: Displays the current servo drive state, such as servo ready or running;
Parameter display: Displays the function codes and their setting values;
Fault display: Displays the fault and warnings occurring in the servo drive;
Monitoring display: Displays the current running parameters of the servo drive.
Axis No. display: Displays the axis number currently operated and displayed.
Figure 4-2 Diagram for switching between different display
Power on
Status display
Parameter
display
Monitoring
display
Fault display
Switch to group
H0B
Motor static
Setting function code H08-32
Auto switch after motor rotating
Axis number
display
MODE
MODE
MODE
MODE
MODE
SET
SEL
SEL
●
After the power is on, the operation panel enters the state display mode.
● Press the MODE key to switch over between different modes, as shown in the preceding figure.
●
In state display mode, set H02-32 and select the monitored parameters. When the motor rotates, the
operation panel automatically switches over to monitoring display. After the motor stops, the panel auto-
matically restores to the state display.
Summary of Contents for SV820N Series
Page 128: ...127 6 Trial Running 6 2 The definition part of FB 3 Five function blocks in FB...
Page 143: ...142 6 Trial Running 6 3 Open Visual studio and create a New Twincat3 Project...
Page 146: ...145 6 Trial Running 6 Click OK Click OK...
Page 147: ...146 6 Trial Running 6 Click Yes Click OK...
Page 149: ...148 6 Trial Running 6 C The default RPDO list is as follows...
Page 150: ...149 6 Trial Running 6...
Page 152: ...151 6 Trial Running 6 7 Activate the configuration and switch over to the running mode Click...
Page 158: ...157 6 Trial Running 6 Create a new POU...
Page 159: ...158 6 Trial Running 6 Create a new FB add MC_power MC_jog MC_home MC_absolute MC_reset to FB...
Page 160: ...159 6 Trial Running 6 Call axis_motion in main Call the program in PLCTASK...
Page 181: ...Revision History Date Revised Version Revised Details May 2017 A00 First release...