- 16 -
1 Servo System Selection
1
1.3.4 Motor Overload Characteristics
Load Ratio (%)
Running Time (s)
120
230
130
80
140
40
150
30
160
20
170
17
180
15
190
12
200
10
210
8.5
220
7
230
6
240
5.5
250
5
300
3
350
2
Figure 1-8 Motor overload curve
100
150
200
250
1,000
Load ratio (%)
Running time (s)
300
1
10
100
350
●
The maximum torque of H1 and H4 is 3.5 times the rated torque.