‑35‑
2.1.5 Installation Precautions
Table 2–3 Installation precautions
Item
Description
Installation Method
●
Install the servo drive vertically upward to facilitate heat
dissipation. For installation of multiple servo drives inside
the cabinet, install them side by side. For dual‑row
installation, install an air guide plate.
●
Make sure the servo drive is installed vertically to the wall.
Cool the servo drive down with natural convection or a
cooling fan. Secure the servo drive to the mounting surface
through two to four mounting holes (the number of
mounting holes depends on the capacity of the servo drive).
●
Install the servo drive vertically to the wall, with its front
(actual mounting face) facing the operator.
●
The mounting bracket (if needed) must be made of
incombustible materials.
Cooling
As shown in
, leave
sufficient space around the servo drive to allow proper heat
dissipation through the cooling fan or natural convection. Take
the heat dissipated by other devices inside the cabinet into
consideration. Install a cooling fan to the upper part of the servo
drive to avoid excessive temperature rise in a certain area,
keeping an even temperature inside the control cabinet.
Grounding
Ground the grounding terminal properly. Failure to comply may
result in an electric shock or malfunction due to interference.
Summary of Contents for SV660P Series
Page 1: ...SV660P Series Servo Drive Hardware Guide Data code 19011391 A00...
Page 55: ...Installation 54 Figure 2 21 Installing the ferrite clamp...
Page 111: ...Wiring 110 Open collector mode For use of the internal 24 V power supply of the servo drive...
Page 113: ...Wiring 112 Scheme 2 Using the external resistor...
Page 144: ...Maintenance 143...