‑97‑
Model
Dimensions (mm)
Mounting Hole (mm)
Mounting
Hole
Diameter
(mm)
Weight
(kg)
H
H1
W
D
A
B
MD050‑T200G
983
1060
650
377
420
1030
12
130
MD050‑T220G
MD050‑T250G
MD050‑T280G
MD050‑T315G
1203
1358
800
400
520
1300
14
200
MD050‑T355G
MD050‑T400G
MD050‑T450G
Note
For installation and use of the energy feedback unit, see
MD051 Series Active Front End
(AFE) User Guide.
5.4.7 Output Reactor
With an output reactor installed on the output side of the drive, the excessive dV/dt
can be reduced. This can lower the voltage stress on the motor winding to protect it,
lowers the motor temperature, and prolongs the service life of the motor.
Table 5–43 Minimum cable length with the output reactor configured (three phase 380–480
V)
AC Drive Power (kW)
Rated Voltage (V)
Min. Cable Length (m)
0.4
–
3.0
200
–
500
50
3.7
200
–
500
50
5.5
200
–
500
70
7.5
200
–
500
100
11
200
–
500
110
15
200
–
500
125
18.5
200
–
500
135
22
200
–
500
150
≥ 30
280
–
690
150
Table 5–44 Minimum cable length with the output reactor configured (three phase 200‑240
V)
AC Drive Power (kW)
Rated Voltage (V)
Min. Cable Length (m)
0.4
–
3
200
–
500
50
3.7
200
–
500
70
Summary of Contents for MD520 Series
Page 1: ......
Page 16: ...Components 15 Figure 2 2 Components of T5 to T6 models...
Page 19: ...Components 18 Figure 2 5 Components of T10 to T12 models with AC output reactor...
Page 27: ...System Structure 26 Figure 3 9 Control circuit terminals...
Page 43: ...Options 42 Figure 5 2 Dimensions of MD500 AZJ A1T2 through hole mounting bracket and holes mm...
Page 44: ...Options 43 Figure 5 3 Dimensions of MD500 AZJ A1T3 through hole mounting bracket and holes mm...
Page 45: ...Options 44 Figure 5 4 Dimensions of MD500 AZJ A1T4 through hole mounting bracket and holes mm...
Page 46: ...Options 45 Figure 5 5 Dimensions of MD500 AZJ A1T5 through hole mounting bracket and holes mm...
Page 47: ...Options 46 Figure 5 6 Dimensions of MD500 AZJ A1T6 through hole mounting bracket and holes mm...
Page 49: ...Options 48 Figure 5 8 Dimensions of MD500 AZJ A1T8 through hole mounting bracket and holes mm...
Page 54: ...Options 53 The following figures shows the installed copper busbar...
Page 115: ...Options 114 Figure 5 48 Dimension drawing of ferrite clamp...
Page 120: ...Expansion Cards 119 Figure 6 1 Installation position of expansion cards...