background image

 15

HMI user program 

setting
for this cable

In the HMI user project, set the COM2 port as "RS232";
The HMI and PLC must have the same communication protocol and 

data format settings.

 

Precautions on Communication Connection

1)  

Cable requirements: Different cables are required for the connection of 

different external devices. Do not lay the communication cables together with 

the AC power cables or near electrical noise sources. Do not plug/remove the 

communication cables during communication.

2)   To prevent communication faults, ensure that the communication cables for 

connecting the RS485/RS422 device and RS232 device do not exceed 150 m 

and 15 m respectively.

3)   In case of communication failure, the screen displays “Connection failed: 

connection_1, station 1. err:10001” until the communication is established.

4)   If the communication cable is long or passes through an environment with 

electrical noise, use a shielded cable.

 

USB Port

Mini USB: used to connect the PC with a universal USB communication cable, to 

upload/download user configuration program and set HMI system parameters;

Type A: used to connect a USB drive, USB mouse or USB keyboard, plug and play.

 

Ethernet Connection

The 10M/100M adaptive Ethernet port, located on the back of the equipment, can 

be used for:

1. HMI configuration upload/download, system parameter setting and on-line 

configuration simulation;

2. Connection with multiple HMIs to achieve multi-HMI online communication;
3. Communication with the PLC;
4. Connection with a HUB or Ethernet switch through a standard Ethernet cable 

to join a LAN, or connection with the Ethernet port of a PC through a crossover 
cable. Note: Use a shielded cable to ensure stable communication.

Summary of Contents for IT7000 Series

Page 1: ...7070 HMI User Guide Suzhou Inovance Technology Co Ltd Address No 16 Youxiang Road Yuexi Town Wuzhong District Suzhou Service line 400 777 1260 Website http www inovance com Documentation Technical Support ...

Page 2: ...roduct Read this guide carefully before using to ensure safety For details on use of the user program development environment and design of user programs see the help file of InouTouch PAD a software tool developed by Inovance Visit our website www inovance com for the latest version of the guide Reader This manual is intended for users who use or understand Inovance HMI products including electri...

Page 3: ...nal injury or damage to the equipment Please keep this guide well so that it can be read when necessary and forward this guide to the end user Control system design WARNING Interlock circuits and other circuits such as emergency stop conventional protection forward and reverse rotation must be set outside the equipment devices for preventing equipment damage up down and reciprocating movement limi...

Page 4: ...d direct sunlight high temperature flammable gas steam or dust otherwise there is danger of explosion Do not use this equipment in places with tremendous temperature fluctuation or high humidity otherwise condensation may occur inside the equipment and result in equipment damage Ensure that all cables are securely connected to the equipment Loose connection may cause wrong input or output signals ...

Page 5: ...ters that may contain ingredients that are hazardous to health and the environment must be disposed of as industrial wastes Safety Recommendations In the position where the operator directly contacts the machinery part for example where a machinery tool is loaded unloaded or where a machine runs automatically the onsite manual devices and any other alternative means must be carefully arranged and ...

Page 6: ...5 BSL 4QFDJ珝DBUJPOT JHI OPWBODF UPVDI TDSFFO OP5PVDI JODI JODI JODI 4UBOEBSE 5 DPOPNJD 4 1 2 Basic Parameters Item Product Model IT7070E IT7070T IT7070S CPU Cortex A8 600MHz RTC Supported DRAM 128MB DDR3 Flash 128MB SD card slot One Micro SD interface Supports Micro SD cards push push type No SD card interface No SD card interface ...

Page 7: ... Input voltage 24 VDC 20 Rated input current 250mA Panel IP rating Front panel IP65 back cover IP20 Display size 7 inch Resolution 800 x 480 Brightness 350 Display color 24 bit true color Backlight LED Backlight service life 35000hrs Mounting hole dimensions mm 193 x 139 Housing color Silver Silver Black Operating temperature 10 to 55 10 to 55 0 to 50 Storage temperature 20 to 70 Working humidity ...

Page 8: ...ay from cables and equipment with strong interference including AC power cords PLC output modules inverters and relays The input and output cables of the equipment must be shielded and properly grounded 4 The front panel of this equipment is rated IP65 When the equipment is installed in a IP65 rated cabinet the cabinet must retain its IP rating which means liquid sprayed on the cabinet cannot get ...

Page 9: ...IUFO UIF TDSFX ʍ 1VU UIF DMBTQ JOUP UIF NPVOUJOH IPMF Figure 2 2 Installing the HMI 3 Tighten the clasp screws until the equipment is securely fixed on the mounting plate Recommended torque 6 0 0 5 kgfcm to ensure water resistance and prevent deformation NOTE Warning Do not over tighten the screws In case of any question do not hesitate to consult your supplier For compliance with IP65 rating all ...

Page 10: ...tor is included in the delivery 6 Mini USB port The slave USB communication port to download and debug user programs in a PC 2 DB9 male connector Communication port between HMI and peripherals Built in COM1 COM2 and COM3 serial communication ports For IT7070S only COM1 is available for IT7070T only COM1 and COM2 are available COM1 RS422 or RS485 COM2 RS232 COM3 RS485 7 Firmware upgrade port For fi...

Page 11: ... main USB communication port to read write a USB drive and connect devices such as a mouse or a printer 3 2 Wiring Power Connection This equipment is powered by a 24 VDC power supply Connect the positive pole of the external power supply to the 24V terminal and the negative pole to the 0V terminal Connect the grounding wire to the terminal marked with See the figure below 24V 0V Requirements This ...

Page 12: ...This equipment provides a DB9 communication port DB9 male connector and 1 3 built in independent serial communication ports for connecting the PLC AC drive printer or other intelligent devices This equipment supports multiple communication protocols and is often used as a communication master to access data from external devices The following figure shows the DB9 male connector 1 2 3 4 5 6 7 8 9 0...

Page 13: ...Inovance H1U H2U H3U RS422 communication ports Mitsubishi FX1N 2N 3U 3G RS422 communication ports HMI user program setting for this cable In the HMI user project set the COM1 port as RS422 RS485 The HMI and PLC must have the same communication protocol and data format settings 2 H2U 232 CAB order No 15042148 Pin No Signal COM1 RS485 2 Wires COM1 RS485 4 Wires COM2 RS232 COM3 RS485 1 RS485 2 RS232 ...

Page 14: ... for the DB9 male connector on this equipment part number H2U 232 CAB order number 15042148 5 1 9 6 Cable Connector and Pin DB9 Female Connector 8 Pin Din Round Connector Signal level RS232 built in RS232 RS422 switching circuit RS422 Cable connection Pin No Signal Pin No Signal 1 4 TX 2 RXD 7 TX 3 TXD 1 RX 4 2 RX 5 GND 3 GND Compatible HMI and Port IT5xxx HMI COM2 RS232 IT6xxxE HMI COM2 RS232 IT7...

Page 15: ...n_1 station 1 err 10001 until the communication is established 4 If the communication cable is long or passes through an environment with electrical noise use a shielded cable USB Port Mini USB used to connect the PC with a universal USB communication cable to upload download user configuration program and set HMI system parameters Type A used to connect a USB drive USB mouse or USB keyboard plug ...

Page 16: ...AMD 2GHz or faster 2 Memory 1GB or above 3 Hard disk space at least 1 GB free space 4 Display color display with resolution of 1024 x 768 or above 5 Ethernet port or USB port for uploading downloading screen program 6 Operating system Windows 7 or Windows 10 Connect an Inovance PLC to the port of the product as shown in the figure below GFNBMF DPOOFDUPS UIFSOFU DBCMF NJOJ 64 64 1PXFS TVQQMZ DBCMF ...

Page 17: ...r you enter the system setup password the system setup menu pops up Tap the Calibrate menu item Detailed Steps 1 After entering the calibration mode you will see in the upper left corner of the screen as shown below 2 Use the stylus or your finger to tap the center of will move in the route as shown by the arrows below Tap each point where stops 3 After the 5 point calibration is completed will di...

Page 18: ... disasters and secondary disasters 3 Hardware damage caused by dropping or transportation after procurement 4 Failure to operate the product by observing the User Manual provided by Inovance 5 Faults and damages caused by factors outside of the product such as peripheral devices If there is any failure or damage to the product correctly fill out the Product Warranty Card The maintenance fee is cha...

Reviews: