Inova-bg IP Tau User Manual Download Page 16

IP Tau 

User Manual v1.0 

 

 

Inova-bg Ltd. 2016 

Page 16 of 16 

 

9.2.

 

Communicator/Dialer connection 

 

 
IP Tau has a built-in communicator/dialer receiver. It can receive data from each security panel 

with communicator/dialer option. Settings for the security panel (in some models additional settings 
may also need to be made): 

 

Phone Number:  

Protocol:  

 

Ademco Contact ID 

Wait Dialtone:  

Disable

 

 

 

10.

 

Windows Network configuration 

If  you  want  to  access  the  web-server,  your  computer  must  be  in  the  same  IP  subnet.  You 

must change the settings of your network adapter ( if they are different than needed ). 

If  your  computer  is  in  a  different  network  than:  192.168.1.xxx  with  mask  255.255.255.0 

you will need to change your current configuration of Windows network: 

Start 

  Control  Panel 

  Network  and  Sharing  Center 

  Change  adapter  settings 

 

Right-Click on your network adapter 

 Properties 

 Right-Click on Internet Protocol Version 

 Properties 

 Use the following IP address 

IP Address :   192.168.1.xxx, xxx is between 2 and 254 and must be different than 230 
Subnet Mask:  255.255.255.0

 

 

Summary of Contents for IP Tau

Page 1: ...IP Tau User Manual v1 0 Inova bg Ltd 2016 Inova bg Ltd IP Tau...

Page 2: ...ers 7 4 1 General settings 7 4 2 General IP settings 8 4 3 Settings for the IP Servers 9 4 4 Settings for the digital inputs 10 4 5 Saving the new configuration 11 5 Username and password configuratio...

Page 3: ...ith 10 100 1000Base T Networks Static or dynamic IP address compatible with DHCP server Capability to use one or two fully independent IP servers Verification with an unique ID code HTML server for ea...

Page 4: ...Six digital inputs Capability to use communicator as input using Ademco Contact ID protocol Configurable working mode for every digital input Normal Open Normal Close Check for AC voltage from 5V to...

Page 5: ...a or any other web browser and enter the IP Tau s address http 192 168 1 230 or the new one if you already change it Alternatively you could write http iptau If the device is accessible from that comp...

Page 6: ...ages received from the communicator and the current state of each digital input Through the menu you could select one of the following actions Home Homepage Device Config Configuration of the main par...

Page 7: ...g with Ademco Contact ID protocol each of the four symbols must be from 0 to 9 and or from B to F If working with LARS protocol The first 3 symbols must be from 0 to 7 The last symbol must be from 0 t...

Page 8: ...In this case easy way to access the web server is by entering the following address http iptau If you select this mode but after reboot the device cannot find a dhcp server for more than 10 seconds IP...

Page 9: ...t Use Periodic Test on Server 1 and set the period If Use Backup Server option is enabled a secondary IP Address could be set If the server on the primary address is not available the device will try...

Page 10: ...al close N O or normal open N C contact check for AC on this input Hardware AC or you can disable the input Not Used When digital input is connected to PGM or dry contact for 0 state is accepted value...

Page 11: ...configuration When you click the Save Config button a validation check is performed If there is invalid data in one or more fields they will be colored in red Additionally under the button Save Confi...

Page 12: ...r both fields is 11 symbols If you forget your credentials you can perform a hardware reset to recover default settings Username root Password admin When you click the Save Config button a validation...

Page 13: ...016 Page 13 of 16 6 Utility In Utility menu connections to the servers can be tested When the test button is clicked the device will send test messages to the server If a backup server is enabled the...

Page 14: ...can t reach the device or if you forgot your username or password IP Tau is capable to return to its factory defaults For this purpose you must disconnect from power supply push and hold the button fo...

Page 15: ...1 0 Inova bg Ltd 2016 Page 15 of 16 9 Hardware Connections 9 1 Hardware AC Each of the digital inputs could be used as a Hardware AC input In this mode it will monitor the AC and generate a message fo...

Page 16: ...to access the web server your computer must be in the same IP subnet You must change the settings of your network adapter if they are different than needed If your computer is in a different network t...

Reviews: