5 -1 5 . I f I nve r t e r PCB Pow e r is not supplie d
5 . Se lf Dia gnosis & Trouble Shoot ing
Start
Is the fuse on AC
110V/220V down?
Is the fuse on MAIN
PCB down?
YES
NO
Replace FUSE & check the
root cause
Check the wire connection
YES
Is DC 300V
applied between both
ends of BD1+,-?
NO
Replace FUSE - 250V 6.3A
Check PCB PATTERN &
Replace BD1
[ Caution]
At the INVERTER PCB Power, AC
110V/220V power and over DC
300V of high-voltage are applied.
Please take care of yourself when
repair and measure.
- See the operations and
reference in this manual
when check the MAIN PCB.
Is 110V/220V
applied between both end of PCB
inverter CN101 "1” and
CN102 "3”?
NO
YES
NO