Start
Are the all deforst
heater normal?
YES
Check the bimetal, heater
disconnection, wiring
connection etc.
NO
Replace the applicable sensor
NO
5 . Se lf Dia gnosis & Trouble Shoot ing
Is defrost sensor by
self-diagnostic normal?
YES
**Measuring point of resistance value
according to heater**
F-DEF : CN70#9(Brown)
↔
CN70#13(Gray)
measuring resistance value(63 ohm
±
7%)
R-DEF : CN70#7(White)
↔
CN70#13(Gray)
measuring resistance value(120 ohm
±
7%)
** 0
Ω
: Short trouble /
∞Ω
: Open(bimetal, heater)
trouble
Refer to self-diagnostic
function in the manual
Reference to the manual “Self-Diagnostic”
5 -6 . I f de frost doe s not ope rat e (F,R DEF H e at e r)
R DEF ERROR
F DEF ERROR
To do list
• If defrost has trouble, select the self-diagnostic function to detect the error of defrost heater before
Power Off. (Check the function with the self-diagnostic function)
Summary of Contents for AW3-PJT
Page 17: ...1 7 Principle Of Freezer 1 Product Information To do list https appliancetechmanuals com ...
Page 182: ...6 1 PCB Layout w ith part position 6 PCB Diagram To do list https appliancetechmanuals com ...
Page 188: ...7 Wiring Diagram To do list 7 1 Model RFG295AA BETTER https appliancetechmanuals com ...
Page 189: ...7 Wiring Diagram To do list 7 2 Model RF4287AA BEST https appliancetechmanuals com ...
Page 190: ...7 Wiring Diagram To do list 7 3 Model RFG299AA 7 LCD https appliancetechmanuals com ...
Page 191: ...7 Wiring Diagram To do list 7 4 Model RFG294AA SEARS https appliancetechmanuals com ...
Page 194: ...8 2 CIRCUIT DIAGRAM 8 2 1 Main To do list 8 Schematic Diagram https appliancetechmanuals com ...
Page 208: ...The End Thank you https appliancetechmanuals com ...