Start
Is MAIN PCB
connector (CN51,CN79,CN76)
inserted correctly?
Is Tank Water Heater
normal?(about 60ohm)
YES
Bad contact of connector/
insert correctly
NO
YES
NO
5 -1 . I f t he t rouble is de t e c t e d by se lf-dia gnosis
5 . Se lf Dia gnosis & Trouble Shoot ing
11) Ice Duct Heater(option) has trouble
Is the input voltage of IC01
MICOM #50 normal?
ERROR Code
To do list
YES
NO
Heater
Micom
(IC01)
Initial
power On
Heater
off
Working
heater
Ice
Duct
#50
3.5V ~
4.8V
3.5V ~
4.8V
0V
1) Wire connector
2) Replace Heater
1) Recheck the wire
2) Replace PCB MAIN
Is Tank Water Heater
normal?(about72ohm)
Heater
Ice Duct
Connector
CN51-#2
↔
CN79-#2
ohm
60ohm
±
7%