Start
Is MAIN PCB
Connector CN30 and CN76 inserted
correctly?
Is R Sensor
unit normal?
YES
Bad contact of connector/
insert correctly
NO
YES
NO
5 -1 . I f t he t rouble is de t e c t e d by se lf-dia gnosis
5 . Se lf Dia gnosis & Trouble Shoot ing
2) If R Sensor has trouble
Is the voltage between
MAIN PCB Connector CN30#6
(White) and REG1 HEAT-SINK
normal?
NO
NO(0.6V > Measurement < 4.6V)
Sensor MICOM/Connector number
R
Connector CN30#6(White)
to REG1 HEAT-SINK PCB
typical Ground
Voltage measured between 4.6V ~ 0.6V.
Replace the temperature
sensor
Recheck the wire connection
part
Refer to circuit diagram in the manual
DATA1. Temperature table
** Measuring point of resistance value
according to Sensor **
R : CN30#6
↔
CN76#1 measuring
resistance value
** 0
Ω
: Short trouble /
∞Ω
: Open trouble
ERROR Code
To do list
YES
Summary of Contents for AW3-PJT
Page 17: ...1 7 Principle Of Freezer 1 Product Information To do list https appliancetechmanuals com ...
Page 182: ...6 1 PCB Layout w ith part position 6 PCB Diagram To do list https appliancetechmanuals com ...
Page 188: ...7 Wiring Diagram To do list 7 1 Model RFG295AA BETTER https appliancetechmanuals com ...
Page 189: ...7 Wiring Diagram To do list 7 2 Model RF4287AA BEST https appliancetechmanuals com ...
Page 190: ...7 Wiring Diagram To do list 7 3 Model RFG299AA 7 LCD https appliancetechmanuals com ...
Page 191: ...7 Wiring Diagram To do list 7 4 Model RFG294AA SEARS https appliancetechmanuals com ...
Page 194: ...8 2 CIRCUIT DIAGRAM 8 2 1 Main To do list 8 Schematic Diagram https appliancetechmanuals com ...
Page 208: ...The End Thank you https appliancetechmanuals com ...