background image

33" Electric Fireplace

MODEL:

SAVE THESE INSTRUCTIONS

FOR FUTURE REFERENCE

   

This manual will enable you to obtain a safe, efficient and dependable 

installation  and  operation  of  your  electric  fireplace.  Please  read  and 

understand these instructions before beginning your installation.

Do not alter or modify this fireplace or its components under any circum-

stances. Any modification or alteration of the fireplace system, including 

but not limited to the fireplace and accessories, may void the warranty, 

listings and approvals of this system and could result in an unsafe and 

potentially dangerous installation.

IMPORTANT! IF OPTIONAL gLASS DOORS ARE PURCHASED, TO

ASSURE PROPER ALIgNMENT, INSTALL THIS FIREPLACE IN A

SqUARE AND PLUMb CONDITION, USINg SHIMS AS NECESSARy 

AT SIDES. THIS APPLIANCE IS MOUNTED ON RUbbER FEET TO 

ENSURE ADEqUATE AIR CIRCULATION bENEATH FIREPLACE.   

DO NOT bLOCK AIRFLOW AT THE bOTTOM AIR INTAKES.

INSTALLER:  DO NOT DISCARD THIS MANUAL

PLEASE LEAVE FOR THE HOMEOWNER

FOR yOUR SAFETy

DO  NOT  STORE  OR  USE  gASOLINE  OR  OTHER  FLAMMAbLE

VAPORS AND LIqUIDS IN THE VICINITy OF THIS OR ANy OTHER

APPLIANCE.

electric fireplaces are designed for use as a decora-

tive  appliance  and/or  as  a  supplemental  heater.      They  are 

not intended for continuous use as a primary heat source.

A French manual is available upon request. Order P/N 850,032CF
Ce manuel d’installation est disponible en francais, simplement en 

faire la demande. Numéro de la pièce 850,032CF.

INSTALLATION AND 

OPERATION INSTRUCTIONS

Report # C1482763

2

C

US

®

DrAFt

06-06-06

Publication:506009-10

 Innovative Hearth Products

MPE33-2,ERT3033,Capella 33

Summary of Contents for Capella 33

Page 1: ...IREPLACE IN A SqUAREANDPLUMbCONDITION USINgSHIMSASNECESSARy AT SIDES THIS APPLIANCE IS MOUNTED ON RUbbER FEET TO ENSURE ADEqUATE AIR CIRCULATION bENEATH FIREPLACE DO NOT bLOCK AIRFLOW AT THE bOTTOM AI...

Page 2: ...HIS APPLIANCE OUT DOORS DO NOT EXPOSE FIREPLACE TO THE ELEMENTS SUCH AS RAIN ETC THIS APPLIANCE IS NOT INTENDED FOR USE IN BATHROOMS LAUNDRY AREAS OR SIMILAR INDOOR LOCA TIONS NEVER LOCATE THIS APPLI...

Page 3: ...tall or operate this fire placethroughaswitchwiredinthe 120VACor 240VACcircuits The only approved wiring for a switch is through the low voltage circuit 24 VAC as shown on Page 14 gENERAL INFORMATION...

Page 4: ...m 5 1 4 134 mm 24 1 2 622mm 27 1 2 700mm 21 1 8 537 mm Electrical Access Cover Power Cord Electrical Access specifications Front View Side View 36 1 4 921 mm 25 5 8 35 1 4 651 mm 895 mm 51 1 4 1302 mm...

Page 5: ...event overloadingahousecircuitincasesofhaving multiple appliances on the same circuit Use an outlet that is protected by a ground fault circuit interrupter where required by electrical code 4 If appli...

Page 6: ...ff Off Off Heater On Off center switch Manual Control Switches are located behind pull screen on inside floor Note Ensurethecircuitbreakersforthepower supply are turned on This appliance can be operat...

Page 7: ...activate the lights Note If the flame does not come on immedi ately adjust brightness and intensity buttons E K 4 To increase the brightness press and release the light brighten button see E Each time...

Page 8: ...re the mounting plate Remove the 4 side screws first 2 on each side Remove the middle screw that is on the top of the handle last b Slowly lower the heater blower assembly and let it rest on the 2 sup...

Page 9: ...9 L1 BLACK POWER L2 ORANGE POWER G GREEN GROUND N WHITE COMMON N1 BLUE COMMON N2 BLUE COMMON Outer Wall WARNINg Donotinstalloroperatethisfireplacethroughaswitchwiredinthe120VACor 240VACcircuits Theonl...

Page 10: ...HOME POWER SUPPLy 240 VAC 120 V L1 120 V L2 240 V FIREPLACE WIRE HARNESS 120 VAC 120 VAC WHITE bLACK ORANgE bLUE bLUE yELLOW AND gREEN gROUND N L1 L2 240 V 3000 W gROUND N L1 L2 N1 N2 See Power Suppl...

Page 11: ...MS optional kits see Page 17 When using the manual control panel power on off switch the outside power on off switch optional wall switch kit must be in the OFF position When using the outside power o...

Page 12: ...ostat per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the the black and white wires...

Page 13: ...witch per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the 2 red wires and pull out t...

Page 14: ...e defective qualified service technician Inspect all wiring for loose connec tions Ifthewireconnectionsaregood replace the flame motor 3 Fflame sputters Flame motor is defective qualified service tech...

Page 15: ...each H5043 1 9 FCA3336 Flame Cylinder Assembly led models H9109 1 10 Flame Motor H9112 1 11 1 12 Log ember bed 33 H9113 1 13 Panel bottom Front H1946 1 14 Panel Flame Cover H1947 1 15 Panel Louver Up...

Page 16: ...REPLACEMENT PARTS COMPONENT DIAgRAMS 8b 14 16 11 1 4 2 5 6 6 7 12 13 15 23 17 19 8a 3 20 9 Front View 18 22 FLAME bLUE yELLOW POWER ON OFF ON OFF DISPLA Dimmer righter EM ERS HEATER ON OFF TEMP CONTR...

Page 17: ...iption 89L36 WTK Wall Thermostat Kit Wall Switch Kit Trim Kit glass Enclosure Kit This kit contains trim panels used to finish the gaps between the wallboardand the fireplace providing the appliance a...

Page 18: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 18 NOTE THIS PAGE LEFT BLANK INTENTIONALLY NOTES...

Page 19: ...design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A Innovative Hearth Products 506...

Reviews: