Specifications are subject to change without notice. No liability accepted for errors or omissions.
8
•
Remote monitoring of DC system via internet con-
nection
•
BCT controlled via web page or SNMP MIB browser
•
Includes all the features of our standard
No-Break
DC
UPS systems
•
Separate outputs for load and battery
•
Battery detection - regular battery presence and
battery circuit integrity checks
•
Deep discharge protection for battery
•
ECB for overload protection of battery circuit
•
Fused reverse battery polarity protection
•
Automatic temperature compensated output volts
•
No-Break
switching between PSU & battery
•
LED flash codes for precise state indication
•
Two alarm relay outputs st BCT relay
ENVIRONMENTAL
Operating
temperature
Storage temperature
Humidity
Cooling
♦
24 Month Warranty
AC Input
Frequency
Fusing / Protection
Isolation
Efficiency
Inrush current
Output Power
Output Voltages
Voltage adj. range
Temp. Compensation
Current Limits
Line Regulation
Load Regulation
Noise
Drift
Hold-up time
Thermal Protection
OVP
Battery Condition Test
(BCT)
ELECTRICAL
230V AC: 180V - 264V (standard)
110V AC: 88V - 132V (on request)
45- 65 Hz
Input fuse
Output fuse & ECB for battery
1KV DC input - output / earth
> 85%
Soft start circuit
750W
13.8, 27.6, 34.5, 41.4, 55.2V
85 - 105% of Vout
Temperature sensor on 1.7m lead with adhe-
sive pad: -4mV / °C / cell ±10%
PSU:
100% rated current
Battery:
25-100% PSU current
<0.2% over AC input range
<0.4% open circuit to 100% load
<1%
0.03% / °C
15 - 20 ms (nom. - max. Vin) without battery
Yes, self resetting
Over-voltage protection on output
at ~ 130% of nominal output voltage
Settings to be specified at time of order.
Control of BCT is implemented using the
SNMP software.
BCT relay provided to control an external test
load. Please do not hesitate to ask our sales
staff for assistance with this feature.
0 - 50 °C ambient at full load
De-rate linearly >50 °C to no load @ 70 °C
-10 to 85 °C ambient
0 - 95% relative humidity non-condensing
Fan cooled
No-Break
™ FUNCTIONS AND ALARMS*
Battery Charge Limit
Reverse Polarity
Battery Monitoring
Battery Protection
-
low battery volts
-
overload
- short circuit
Indication LEDs
Alarms
Alarm Relay contacts
Standby Mode
See Model Table for default settings -
may be increased to PSU rated current
Battery reverse connection will open internal
fuse (and produce alarm)
Detects for presence of battery on start up,
then every 60 minutes when charge current <
200mA
Electronic Circuit Breaker (ECB) operates
under the following conditions:
•
battery voltage drops to 1.67V/cell -
auto reset
•
< 300ms for load > 6 x rated PSU cur-
rent, allows ~1.5x rated PSU current
from battery without acting,
•
< 2ms, backed up by fuse
Green:
Battery System OK, Power OK
Red:
Standby
•
Power OK (Mains/PSU fail, standby
mode)
•
Battery System OK - alarms when battery
voltage low (on mains fail) , battery miss-
ing, battery circuit wiring faulty, BCT fail (if
enabled)
C - NO - NC full changeover rated 1A /50V
DC, 32VAC
Turns off DC output of PSU & allows load to
run off battery
STANDARDS
EMI
Safety
to CISPR 22 / EN55022 class A
to IEC950 / EN60950 / AS/NZS3260
Optional internal V/I
meter shown
SPECIFICATIONS
All specifications are typical at nominal input, full load and at 20°C unless otherwise stated.
With Ethernet (SNMP) communication port