9.3.1.8 Outdoor temp. too low protection(Optional for some models)
Check if the outdoor ambient
temperature is beyond the normal
operation temperature range.
Yes
No
Replace the outdoor ambient
temperature sensor.
Turn on the unit when outdoor
ambient temperature is in normal
operation temperature range.
9.3.2 Outdoor unit trouble shooting
9.3.2.1 E0(Outdoor EEPROM malfunction) error diagnosis and solution
Error Code
E0
Malfunction decision
conditions
PCB main chip does not receive feedback from EEPROM chip
Supposed causes
●
Installation mistake
●
PCB faulty
Trouble shooting:
If the EEPROM chip
is welded on PCB,
replace the PCB
directly. Otherwise,
check whether the
EEPROM chip
plugged in PCB well?
Yes
No
Yes
Insert the EEPROM well
Replace the outdoor main board
Outdoor EEPROM malfunction
9.3.2.2E4(open or short circuit of outdoor temperature sensor) diagnosis and solution
E1/E2/E3/E6 (open or short circuit of indoor coil temperature sensor) diagnosis and solution.
The same as E5/ E6 in indoor.