Dial-Tone Timeout
Will play Dial Tone for this period of time
and then play fast busy.
Reorder (Fast
Busy) Tone Time
Out
Will play fast busy tone for this period of
time and then play Howler tone.
OSI Duration
When a call is terminated, place line in
open circuit for X ms. A value of 0 disables
OSI.
Jitter Buffer
Setting
Jitter Buffer Mode
•
Adaptive
–
Jitter Buffer Size changes
during the call in response to network
conditions.
•
Fixed
–
Jitter Buffer Size stays at the
programmed value.
•
NetEQ
–
when NetEQ is selected, the
‘Initial Jitter buffer size,’ and
‘adapt
at
ion Min Depth’ values are not
used.
Initial jitter buffer
size
The initial jitter buffer size in ms.
Adaptation Min
Depth
If network conditions are good, and no late
packets are detected, the jitter buffer will
continue to decrease until it meets the
configured size.