Innogy eStation Operating Instructions Manual Download Page 9

9

9

Operating instructions

The operating mode is indicated by 
the LED above the key switch. 
The following modes are indicated:  

“Off”

LED display is off

Charging station operational

LED indicator illuminates white

Vehicle connected

LED indicator illuminates green

Charging active

LED indicator illuminates blue

Charging impossible

LED indicator illuminates red

Charging station faulty

LED indicator fl ashes red

Risks for humans and the environment 

•  Stumbling injury due to improper laying of 

cables

•  There is a danger of electric shock where 

defective cables are involved.

•  There is a risk from road traffi c when installing 

and removing the cable in areas where there is 
heavy traffi c.

Protective measures and rules of conduct

•  The charging cable should be routed so 

that no risk of stumbling occurs due to the 
installation.

•  When plugging in the charging cable, ensure 

that only charging cables are used that are 
visibly and technically sound and intended for 
charging.

•  Pay particular attention to road traffi c on busy 

roads.

•  Do not attempt to repair defective cables.

Conduct in event of malfunctions  

•  Have defective charging stations repaired 

immediately by appropriate skilled personnel.

•  Do not establish an electrical connection if 

charging cables or charging points are 
defective.

Maintenance or replacement of charging 
cables

•  Defective cables must be repaired or replaced 

by a qualifi ed person.

•  Defective cables must not be used any further 

on the eStation.

Conduct in case of accidents, fi rst aid

•  Switch off the power.
•  Provide fi rst aid and secure the danger

zone. Emergency no.: 112

•  Make an emergency call and initiate rescue.

Using the charging cable 

The following information is provided for the 
safe laying of cables for charging of electric 
vehicles on the innogy charging station. The 
user of the eStation is responsible for the safe 
handling of charging cables. 

!

!

!

!

!

Summary of Contents for eStation

Page 1: ...innogy eStation IEIA 152 Operating instructions innogy com emobility ...

Page 2: ...innogy eStation IEIA 152 2 ...

Page 3: ...tions Contents 4 Refuelling is now charging 5 Basic safety instructions 6 Scope of delivery 7 Technical data 8 Operation for charging an electric vehicle 10 Inspection maintenance 11 Error messages 20 03 2018 Version 1 0 ...

Page 4: ...for the rapid charging of electric vehicles We are delighted that you have chosen the innogy eStation and hope you will be happy as you join us on our common journey designing the refuelling of the future Your eMobility team innogy SE 4 innogy eStation IEIA 152 Very important information Instructions which particularly relate to safety i ...

Page 5: ... Additional training is mandatory The product may not be converted or modified The manufacturer will not bear any liability for unilateral modifications to the product Only suitable accessories may be used with the product Only spare parts listed by innogy in the spare parts catalogue and consequently approved may be used for repairs We reserve the right to make technical changes in the context of f...

Page 6: ...station is EMC tested and meets the requirements of EMC Directive 2014 30 EU and the Low Voltage Directive 2014 35 EU Instructions in manuals for mobile wireless communication devices must be observed when using in the vicinity of mobile wireless communication devices Following each charging the charging cable connected to the innogy eStation is disconnect ed electrically from the power supply net...

Page 7: ...tion No of charging points Output Vehicle recognition Two charging sockets type 2 Max 11 kW configurable 400 V 3 16 A per charging point Via pilot signal pursuant to IEC 61851 1 2012 Display Multicoloured LED indicates charging charge status and error message Protection technology Integrated for each charging point Personal protection RCD type B 30 mA for DC residual currents and 6 mA for AC residu...

Page 8: ...ogy eStation remains on for the duration of charging and ultimately deactivates itself automatically The plug lock only opens during this if the cable on the vehicle is unplugged Operating modes Ladevorgang beenden Aus Ein 1 Off Ladevorgang beenden Aus Ein 2 Permanently on Ladevorgang beenden Aus Ein 3 Operational for the next 60 seconds 1 2 60 sec Ladevorgang beenden Aus Ein 4 Deactivation Aus La...

Page 9: ...ging in the charging cable ensure that only charging cables are used that are visibly and technically sound and intended for charging Pay particular attention to road traffic on busy roads Do not attempt to repair defective cables Conduct in event of malfunctions Have defective charging stations repaired immediately by appropriate skilled personnel Do not establish an electrical connection if charg...

Page 10: ...s a third party who has undergone training approved by innogy or undertakes repair him or herself innogy can be commissioned with repair work within Germany Repair includes the measures necessary to restore the charging station to a safe and functional condition In the event of damage being detected during an inspection maintenance damaged parts should be replaced immediately in as far as possible...

Page 11: ... cable is defective Please replace the charging cable with a certi fied charging cable suitable for your vehicle LED flashes rapidly green 5 x per second The vehicle signals invalid current values Please disconnect the vehicle from the charging cable and start the complete charging procedure from the beginning Please contact the manufacturer of your vehicle if the fault persists LED remains permanen...

Page 12: ...innogy SE Flamingoweg 1 44139 Dortmund Germany emobility innogy com innogy com emobility P EFFG 65 09 17 ...

Reviews: