Splicing operation
How to use keypad
•
Turning splicer on
•
Select splice mode
•
When splicing only standard SM fibers (ITU-T G.652),”SM AUTO” mode is recommended.
•
When splicing different types of fibers, “AUTO” mode is recommended, but splice speed is slower.
•
Splicing speed of “SM FAST” mode is faster, but periodically Arc calibration is required.
•
Check splicing and heater modes
•
Cleaning fibers
•
Place the sleeve on the fiber
•
Stripping fiber
•
Cleaning fiber
•
Cleaving fiber
•
Install fiber onto splicer
•
Start splicing by closing wind proof cover
•
Visual inspection on LCD during splice
•
Remove the spliced fiber
•
Centering protection sleeve on spliced fiber
•
Put the sleeved fiber into heater
•
Start heating by closing heater cover
•
Completed
Copyright
ⓒ
2013 INNO Instrument Inc. All rights reserved.
65-3 Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do 462-807, Republic of Korea
Tel: +82 31 742 8755 Fax: +82 31 742 8799
www.innoinstrument.com
IFS-10 ARC Fusion Splicer
Quick Reference Guide
!
Insert fiber into the protection
sleeve
Cleaning fiber
•
Make sure the stripped fiber is free of coating debris or dust.
•
Use only 99% or better purity alcohol.
•
Clean by clean wipes (dustproof)
•
Keep the cleaved fiber ends face in clean condition.
•
Place the fiber end between V-groove edge and
Electrode center.
V-groove
edge
Electrode
center
Battery pack
How to recharge battery
Battery Pack
AC Charger
•
Connect battery pack (LBT-20) with AC charger, power cable.
•
Do not stack battery pack on top of charger while recharging.
•
Recharging temperature: 0~40
°
C (32~104
°
F).
CAUTION
Confirm power saving function is working when using battery pack.
!
Hold
Hold
Spliced point
Pull
Pull
•
Hold the fiber at edge of splicer body
•
Gently pull the fiber
Ver.1.0
CAUTION
When ARC discharge is not stable. Electrodes should be stabilized and calibrated to
reform the arc discharge. Install prepared SM fibers onto splicer to operate stabilize
electrodes and arc calibration. After installation SM fibers, splice fibers again.
250um
8~16mm
1/3"~2/3"
8~16mm
1/3”~2/3"
900um
13mm
1/2"
Less than 3mm
1/8"
Fiber Holder
Description
ON/OFF Key
Power ON/OFF
ARROW Key
Move cursor
change value
MENU Key
Open [Main Menu]
CANCEL Key
Return to
previous screen
OK Key
Enter
HEAT Key
Heater ON/OFF
when auto heating is off
LED
Turn ON Press key until green led turns on
Turn OFF
Press key until green led blank
ARC Key
Generate ARC
RESET Key
Stop and back to ready
SET Key
Execute splice when
auto start is off
XY Key
Switch X and Y images
How to check remaining capacity
on “READY” screen
Battery checking button