EDAM-4200 Series User’s manual Version 1.03
8.4.9
~AATNN
Sets the soft INIT* timeout value
Description: The Soft INIT* command is used to enable modification of the IP, Gateway and communication
protocol settings using software only.
Command:
~AATNN [CHK](cr)
Syntax:
~
Command leading code
AA
Module address ID (01 to FF , Always 01)
T
command to Sets the soft INIT* timeout value
NN
Two hexadecimal digits representing the timeout value in seconds. The
maximum timeout value is 60 seconds. When changing the IP or Gateway
settings without altering the INIT* slide switch, the ~AAI and (or $AAS1)
commands should be sent consecutively and the time interval between the
two commands should be less than the soft INIT* timeout. If the soft INIT*
timeout is 0, then the IP and Gateway settings cannot be changed using
software only. The power-on reset value of the soft INIT timeout is 0.
CHK
Check sum
(cr)
Carriage return
Response:
!AA [CHK](cr)
Valid command
?AA[CHK](cr)
Invalid command
!
Delimiter for valid command
?
Delimiter for invalid command
AA
Module address ID
CHK
Check sum
(cr)
Carriage return
Example :
1.
Sets the soft INIT* timeout value of module 01 to 16 seconds and returns a valid response.
Command:
~01T10(cr)
Response:
!01(cr)
2.
Sets the soft INIT* enable and returns a valid response.
Command:
~01I(cr)
Response:
!01(cr)
3.
Reloads the module factory default
Command:
$01S1(cr)
Response:
!01(cr)
Related command:
~AAI, $AAS1
Printed Date: 27 February 2018
94