Air2-Smarty/W
Wireless indoor sounder/flasher
Installation and programming manual
Page 1: ...Air2 Smarty W Wireless indoor sounder flasher Installation and programming manual...
Page 2: ...rty W 9 4 1 Enrolling a wireless device 10 4 2 Battery replacement 11 5 Programming of Air2 Smarty W 12 5 1 Wireless sounder flasher parameters 12 5 2 Real time 13 5 3 Programming the patterns 14 6 Ge...
Page 3: ...magnetic contact with two I O terminals l Air2 FD100 smoke detector l Air2 Aria W keypad with graphic display l Air2 Smarty W indoor sounder flasher l Air2 Hedera outdoor sounder flasher l Air2 DT200T...
Page 4: ...gnal LEDs Functions l Piezoelectric horn l Super bright LED technology flasher l 3 6V 2 8Ah battery l Open enclosure tamper protection l Tamper protection device l IP Protection rating30 l Communicate...
Page 5: ...ocations for the cover pin B Battery C Battery connector D ENROLL button E Piezoelectric horn F Tamper microswitch Dislodgement G Tamper microswitch Open cover H Red STATUS LED I Green PRG LED J LED f...
Page 6: ...dby 50 A maximum 200 mA Acoustic output type tones Sound pressure at 1m 85 dB A Carrier frequency 1148 Hz Flash rate per minute programmable 36 56 Maximum alarm time programmable 4 min Operating envir...
Page 7: ...programmed will signal device faults and tamper events Audible signalling The speaker emits an audible signal which can be programmed for tone 3 tones available duration volume and associated events 3...
Page 8: ...m sounder signalling time the signalling will be interrupted 3 3 Faults and tampers The STATUS and PRG LEDs will signal fault or tamper conditions on the sounder flasher only when set up to do so duri...
Page 9: ...h the base to the wall 4 Insert the tamper protection screw into its location Description of parts O 5 Connect the battery to the connector on the PCB Description of parts C and place it in its housin...
Page 10: ...utton A window opens where you can select the devices to be configured and add them to the configuration In the section on the left you can increase the number using the button corresponding to the se...
Page 11: ...eripheral sounder Wireless Once the OK button has been pressed it is necessary to work through the menu options in order to enroll it 4 2 Battery replacement When replacing the power supply batteries...
Page 12: ...proceed with the programming of the sounder flasher Note Once the programming has been completed and the parameter have been written on the control panel it will take at least 30 seconds for the devi...
Page 13: ...LED PRG or STATUS provides 5 options which allow you to select the control panel event that will activate the LED Configured sounder flasher selec ted sounder flasher Sounder flasher cut off events A...
Page 14: ...under dura tion Sounder activation time from 1 to 127 seconds or from 1 to 127 minu tes Volume Sound level of the sounder flasher Flash type Checkbox for the selection of the flash rate number of flas...
Page 15: ...tion Tone Volume Flasher Flasher duration Flash type STATUS PRG LED Burglary ON 3 minutes 1 high ON 3 minutes 56 OFF Burglary low volume ON 3 minutes 1 medium low ON 3 minutes 56 OFF Fire ON 3 minutes...
Page 16: ...r or replace the parts of this system have authorization to work only on devices marketed under the brand Inim Electronics 6 3 Notes from the Manufacturer The Air2 devices are certified by IMQ Sistemi...
Page 17: ...o the purchaser or any other person for damage arising from impro per storage handling or use of this product Installation of this Product must be carried out by qualified persons appointed by Inim El...
Page 18: ...waste but must be object of a separate collection Where marked the chemical symbols Hg Cd o Pb indicate that the bat tery contains mercury cadmium or lead above the reference levels of the directive...
Page 19: ...Air2 Smarty W 2021 Inim Electronics S r l 19 6 8 Disposal of the product...
Page 20: ...info inim biz _ www inim biz Via dei Lavoratori 10 Loc Centobuchi 63076 Monteprandone AP I Inim Electronics S r l TALY Tel 39 0735 705007 _ Fax 39 0735 704912 DCMIINE0A2SMARTYW8E 102 20210526...