51
6.8 InHand Device Manager (DM) platform
Table
6-5
Setting platform parameters
Parameters
Description
Default
SN
Set a 15-bit character string for the network management
platform to identify the device.
It is defined when manufacture, cannot be modified.
Empty
DM mode
Only SMS, SMS + IP, or disabled.
Only SMS
White List
The trusted list for accessing DTU, the DTU will interact with
white list phone number by SMS.
If the list is empty, it will receive the SMS of anyone.
Empty
DM ID
Enter the device ID used by the platform to identify the device. 0
DM address IP address, domain name and port number for DM
0.0.0.0/g.inhandn
etworks.com/
20003
Heart beat
interval
Set the heartbeat interval between the DTU and the platform.
The value ranges from 30 to 600 seconds.
120
Update
interval
Set the update interval about DTU state information between
the DTU and the platform. The value ranges from 1 to 65535
seconds.
3600
6.9 Administrator Account
Table
6-6
Setting administrator login parameters
Parameters
Description
Default
Administrator
Set the administrator account name.
adm
Administrator
password
Set the password for the administrator account.
123456
Common user
Set the name of the common user.
adm
Common user
password
Set the password for the common user.
123456
Summary of Contents for InDTU324
Page 1: ...I InDTU332 324 USER MANUAL Version V1 0 November 2019...
Page 29: ...25 Figure 4 8 1 ICMP parameter setting Figure 4 8 2 Link maintenance parameter setting...
Page 36: ...32 Figure4 10 2Viewing real time logs Figure4 10 3Viewing real time logs...
Page 41: ...37 Figure4 11 3 select firmware Figure4 11 4 upgrade firmware...
Page 42: ...38 Figure4 11 4 popup after upgrade Figure4 11 5 confirm the upgrade result...