Overview 

This  document  is  used  to  guide  customer  installing  and  operating  InDTU300  Series  Industrial  GPRS  Data  Terminal 

Unit which researched and developed by InHand Networks. Please make sure the product model and the accessories in the 

packaging (like power supply, antenna) before using. If you need buy SIM card, please consult the local operators. 

Panel Layout 

       

There are two serials ports in InDTU300, COM 1 is for data communications and COM 2 is for configuration. We use 

COM 2 to configure InDTU300

.   

 

Typical application 

InDTU300 series can be used to connect your serial device (RS232/485) to internet via GPRS network. 

 

GND 

COM 1 

Data transmission 

only 

9600 / 8 / none / 1,   

Allow you to change 

the parameters 

TXD/485- 

RXD/485+ 

TXD2 

COM2 

Configuration only 

15200 / 8 / none / 1, 

parameters can be 

changed 

RXD2 

GND 

V- 

Power supply 

 

V+ 

Summary of Contents for InDTU300 Series

Page 1: ...InDTU300 Series Quick Guide Second Edition March 2013 2013 InHand Networks All rights reserved Republication without permission is prohibited...

Page 2: ...M card please consult the local operators Panel Layout There are two serials ports in InDTU300 COM 1 is for data communications and COM 2 is for configuration We use COM 2 to configure InDTU300 Typica...

Page 3: ...on should be carried out when InRouter keep interruption of power supply Link the InDTU300 s terminal with DB9 interface to PC using a USB to DB9 line you can buy it from local tool shops Open the she...

Page 4: ...select the available COM port and enable Auto to let software auto detect InDTU300 or click the Detect DTU to check if connection is correctly If you see the following prompt then you can continue you...

Page 5: ...3 Before configure InDTU300 you d better read the conf file first Click Read Conf File button to get the configure file of InDTU300 Now you can configure what you want...

Page 6: ...e and set as Always Online 5 Click GPRS setting then input the right parameters you get from local mobile operator Auto Dialup On dialup automatically after configuration Off dialup on demand triggere...

Page 7: ...ure the details of where InDTU300 connecting central site DTU No The Number is for identifying InDTU only for DC protocol Center IP User s data center IP address must be a static IP if you have DNS on...

Page 8: ...boot DNS IP1 IP2 Domain Name Server recommended setting 8 8 8 8 8 8 4 4 Google Domain Name Server 7 Finished configuration click Write Conf File to save the configuration into InDTU300 8 You should re...

Page 9: ...ks All rights reserved Tel 86 10 64391099 8022 Fax 86 10 84170089 Address West Wing 11th Floor of Qiming International Mansion No 101 Lize central Park Chaoyang District Beijing Website http www inhan...

Reviews: