ABH2015IQE01_ - Installation and Operation Manual
3TL
6TL
Nominal frequency
50 / 60 Hz
Frequency range
40 ~ 70 Hz
Maximum power
11,500 VA
Maximum current
50 A rms
Cosine of Phi
0 ~ 1
Consumption grid output (AC)
Stand-alone mode
Power (25 ºC) 30 min, 2 min, 3s
(5)
3,500 / 3,900 / 5,080 W
6,400 / 6,900 / 7,900 W
Maximum current
13 A rms
26 A rms
Rated voltage
(6)
220 ~ 240 V
Nominal frequency
(6)
50 / 60 Hz
Cosine of Phi
-0.8 ~ 1 ~ 0.8
Performance
Maximum efficiency
95.5 %
96 %
Euroefficiency
95.1 %
95.2 %
General data
Cooling system
Forced ventilation
Air flow
27 m
3
/h
45 m
3
/h
Weight
24.4 kg
26 kg
Dimensions (height x width x depth)
470 x 360 x 180 mm
Stand-by consumption
< 10 W
Operating temperature
–
20 ~ +65 ºC
Relative humidity (without condensation)
4 ~ 100 %
Protection class
IP65
Pollution degree
2
Maximum altitude
2,000 m
Overvoltage category
Category III (AC) / Category II (DC)
Insulation class
Class I
Markings
CE
EMC and safety regulations
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-
6-4, EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN
62109-2, EN 50178, IEC62103, AS62040.1, FCC Part 15
Distribution grid connection regulations
AS4777.2:2020
(1)
The maximum power of the inverter is a calculation of the battery voltage multiplied by the maximum discharge current (50 A).
(2)
See the list of
compatible Li-Ion batteries.
(3)
In On-grid mode V
MPPmin
= 1.44 x V
AC
(distribution grid voltage). In Off-grid mode V
MPPmin
= 1.44 x V
AC
(rated voltage
configured for the consumption grid).
(4)
Never exceed this value. Consider the voltage increase of the panels ‘Voc’ at low temperatures.
(5)
This power will
be available if the battery voltage multiplied by the maximum discharge current reaches said value.
(6)
This parameter can be set on the display.
14
Unit description
Ingeteam