background image

 

INGECON SUN STORAGE 1Play

 

Technical Guide 

30/09/2019 

4/9

 

2  Connecting the battery pack to the inverter 

The instructions to connect the battery pack to the inverter are described in the “Installation Manual of 
Pylontech” 

Please, take into account the following technical notes: 

1)  The inverter is turned OFF before connecting the battery pack to the inverter. 
2)  The battery circuit breaker is on the OFF position. 
3)  Connect the DC power wires with 6-10mm

2

4)  Connect the CAN Communication wire. 

 

2.1  Wiring of CAN communication wire 

Pylontech batteries require a CAN communication wire to the ISS 1Play. 

The ISS 1Play will send the necessary keep-a-live command to the Pylontech battery, which is needed to 
keep its internal circuit breaker close. When the battery does not receive for 15 seconds such a command, its 
internal circuit breaker opens. 

The ISS 1Play uses a two-pin CAN BAT connector and the Pylontech uses a RJ45. The pin-out is the 
following: 

 

 

It is mandatory that the ISS 1PLAY has its display correctly connected. Otherwise, the Pylontech will open its 
internal circuit breaker after 15 seconds. 

Francisco Javier F.J.A. Ancn Jimenez

2019.10.31 08:36:45

Firmante: 

CN=Francisco Javier F.J.A. Ancn [email protected]=com0.9.2342.19200300.100.1.25=ingeteamrenovables

Llave publica: 

RSA/2048 bits

Summary of Contents for INGECON SUN STORAGE 1Play 3TL

Page 1: ...working with PYLONTECH FORCE H1 H2 and POWERCUBE X1 X2 ABH2010IMC13_ Francisco Javier F J A Ancn Jimenez 2019 10 31 08 36 45 Firmante CN Francisco Javier F J A Ancn JimenezE francisco ancin ingeteam c...

Page 2: ...Black start function 5 4 Battery s firmware update 6 5 Setting the inverter 7 5 1 DC Battery type 7 6 Final check 8 7 Attachment I References 9 Francisco Javier F J A Ancn Jimenez 2019 10 31 08 36 45...

Page 3: ...he inverter FW versions can be found at the display or via the Ingecon Sun Manager software Using Ingecon Sun Manager The firmware version is indicated underneath the inverter serial number Using the...

Page 4: ...cation wire to the ISS 1Play The ISS 1Play will send the necessary keep a live command to the Pylontech battery which is needed to keep its internal circuit breaker close When the battery does not rec...

Page 5: ...3 After 30 seconds press and hold the red start button again for another 5 seconds 4 Then the inverter and battery should get powered Make sure that the display s screen is ON In this situation if the...

Page 6: ...ributor For further details check the Pylontech guideline supplied by the distributor A minimum firmware version is necessary to work with the Ingecon Sun Storage 1Play Force H1 H2 V1 3 Powercube X1 X...

Page 7: ...Lithium Pylontech Force H1 H2 or Settings 1 DC BATTERY TYPE Type of Battery Lithium Pylontech Powercube X1 X2 Figure 1 DC Battery selection on Ingecon Sun Manager Click on the Send button A screen inf...

Page 8: ...an be done using the Ingecon Sun Manager software package or through the display Using the Display MAIN MENU MONITORING BATTERY MONIT STATUS doesn t show BMS ERROR Using Ingecon Sun Manager OnLine Bat...

Page 9: ...un Manager Software Installation Manual of PYLONTECH Force series or Powercube series Ingecon Sun Training https www ingeconsuntraining info page_id 7049 Francisco Javier F J A Ancn Jimenez 2019 10 31...