5.3. Electrical connection
Once the equipment has been mounted in its definitive location, and is firmly anchored in place, the next step is to
make the electrical connections.
DC output
wind turbine
input
ON/OFF
switch
brake
resistor
auxiliary
power supply
analog
inputs
heat sink
communication
5.3.1. Description of cable ports
Whilst the wind is acting on the turbine, the resistor cables could be subject to high voltages that
could be hazardous.
Never manipulate the connections without first performing the shutdown protocol explained in “4.5.3.
Manipulation work”.
The Ingecon
®
μWind Interface cable ports are located at the bottom of the enclosure. Each type is described below:
Communication
To connect the communication cable between the IWI and the Ingecon
®
µWind.
Analog inputs
A general purpose analog input connector.
Auxiliary power supply
Connector for the 230 V single phase cable for the auxiliary power supply to the equipment.
Wind turbine input
Enables the connection between the wind turbine power cable and the IWI.
DC output
To connect the DC voltage power cable between the IWI and the Ingecon
®
µWind.
Braking resistors
The Ingecon
®
μWind Interface models are equipped with a wind turbine resistor braking system. The cable for this
should be passed through this cable gland.