2.2. Remote communication
Remote communication is where the PC (PLC, etc.) and the inverters of the installation are in different networks.
IP1
: 192.168.1.1
IP2
: 192.168.1.2
IP3
: 192.168.1.3
A
D
INTERNET
F
G
F
E
C
B
C
RS-485 wiring
Ethernet wiring
01, 02,
etc.
Modbus node
IP1, IP2,
etc. Ethernet or Wi-Fi
IP Settings:
IP:
192.168.1.X
Net Mask:
255.255.255.0
Gateway:
192.168.1.1
02
IP2
IP3
01
01
IP1
03
04
A. INGECON unit with Ethernet card and RS-485
B. INGECON unit connected to the RS-485 bus
C. INGECON unit connected to the RS-485 bus (end of line)
D. INGECON unit connected via Wi-Fi
E. Router
F. Firewall
G. Remote PC
2.3. Identifying inverters
It is absolutely essential to unequivocally identify each and every one of the inverters of the RS-485 bus.
To establish the node number of an inverter, consult the installation manual of the corresponding
unit.
2.4. Certification
Certification is the process used to compare the transmission performance of a system of wiring installed with a
certain standard using a procedure defined by the standard to measure this performance.
26
Description of the communication
Ingeteam
AAX2023IQM02_A - User manual
Summary of Contents for AAX0057
Page 1: ...Accessories for local and remote communication User manual...
Page 22: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 40: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 58: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 76: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 94: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 112: ...Anmerkungen Notes Notas Remarques Note Notas...
Page 114: ...Ingeteam Power Technology S A www ingeteam com AAX2023IQM02_A 08 2017...