AC-SVX002C-EN
7
Model Number Descriptions
Unit Model Number
Digit 1, 2, 3, 4 — Unit Model
ACSA
= Air-Cooled Scroll Chiller
Digit 5, 6, 7 — Nominal Tonnage
140
= 140 Tons
160
= 160 Tons
180
= 180 Tons
200
= 200 Tons
215
= 215 Tons
230
= 230 Tons
Digit 8 — Compressor Type
2
= Scroll with Variable Volume Ratio
Digit 9— Unit Voltage
A
= 200/60/3
B
= 230/60/3
E
= 460/60/3
F
= 575/60/3
Digit 10— Manufacturing Location
U
= Trane Commercial Systems, Pueblo, CO
USA
Digits 11, 12 — Design Sequence
**
= Factory assigned
Digit 13 — Unit Sound Package
X
= Standard Unit
L
= Superior
R
= Standard with Noise Reduction Request
Q
= Superior with Noise Reduction Request
Digit 14 — Agency Listing
U
=UL/cUL Listing
C
= No Agency Listing
Digit 15 — Pressure Vessel Code
X
= Not Applicable
Digit 16 — Factory Charge
A
= Refrigerant Charge R-410A
B
= Nitrogen Charge
Digit 17 — Auxiliary Items
X
= No Auxiliary Items
Digit 18 — Evaporator Application
N
= Standard Cooling (above 40°F)
P
= Low Temp Process Cooling (below 40°F)
C
= Ice Making
Digit 19, 20 — Evaporator Type
B2
= Brazed Plate Heat Exchanger
(Standard)
Digit 21 — Water Connection
X
= Grooved Pipe
A
= Grooved Pipe + Flange Adapter
Digit 22 — Flow Switch Set Point
C
= Flow Switch Setpoint 15
F
= Flow Switch Setpoint 35
H
= Flow Switch Setpoint 45
L
= Flow Switch Setpoint 60
Digit 23 — Insulation
A
= Factory Insulation — All Cold Parts 0.75
inch
B
= Evaporator-Only Insulation for High
Humidity/Low Evap Temp 1.25 inch
Digit 24 — Unit Application
X
= Standard Ambient (32 to 115°F)
L
= Low Ambient (–20 to 115°F)
H
= High Ambient (32 to 130°F)
W
= Wide Ambient (–20 to 130°F)
Digit 25 — Condenser Length
S
= Standard
Digit 26 — Condenser Fin Options
M
= Aluminum Microchannel
C
= CompleteCoat
™
Microchannel
Digit 27 — Fan Type
E
= EC Condenser Fan Motors
Digit 28 — Compressor Starter
X
= Across-the-Line Starter
Digit 29 — Incoming Unit Power Line
Connection
1
= Single Point Unit Power Connection
Digit 30 — Power Line Connection
Type
T
= Terminal Block
H
= Circuit Breaker with High Fault Rated
Control Panel
Digit 31 — Short Circuit Current
Rating
A
= Default Short Circuit Rating
B
= High Short Circuit Rating
Digit 32 — Electrical Accessories
X
= None
U
= Under/Over Voltage Protection
C
= 15A – 115V Convenience Outlet
B
= Convenience Outlet and Under/Over
Voltage Protection
Digit 33 — Remote Communications
Options
X
= None
B
=BACnet
®
Interface
M
= Modbus
™
Interface
L
= LonTalk
®
Interface
Digit 34 —Hard Wire Communication
X
= None
A
= Hard Wired Bundle — All
D
= Unit Status Programmable Relay
Digit 35 — Smart Flow Control
X
= None
T
= Variable Primary Flow (Constant Delta T)
Digit 36 — Structural Options
A
= Standard Unit Structure
Digit 37 — Appearance Options
X
= No Appearance Options
Digit 38 — Unit Isolation
X
= None
1
= Elastomeric Isolators