Specifications
Full Cool Operation Net Cooling Capacity*
System Net Defrost Heating Capacity
Evaporator Airflow**
**22° pitch fan blades.
R-134a Refrigeration System
Return air to
evaporator coil
inlet
460V, 3 Phase, 60 Hz Power
380V, 3 Phase, 50 Hz Power
Net Cooling Capacity
Power Consp
Net Cooling Capacity
Power Consp
Watts
Kcal/hr BTU/hr
kW @460V
Watts
Kcal/hr BTU/hr
kW @460V
-25 C (-13 F)
10,000
8,600
34,130
17.0
8,300
7,138
28,325
14.1
-55 C (-67 F)
6,000
5,160
20,475
13.0
4,980
4,284
17,000
10.8
*System net cooling capacity with a 37.8 C (100 F) ambient air temperature.
Heater Type
460V, 3 Phase, 60 Hz Power
380V, 3 Phase, 50 Hz Power
Heating Capacity
Heating Capacity
Watts
Kcal/hr
BTU/hr
Watts
Kcal/hr
BTU/hr
Electric resistance rods
8,160
7,018
27,850
6,000
5,160
20,475
External Static
Pressure (water
column)
460V, 3 Phase, 60 Hz Power
380V, 3 Phase, 50 Hz Power
Low Speed
Low Speed
m
3
/hr
ft
3
/min
m
3
/hr
ft
3
/min
0 mm (0 in.)
3,700
1,835
2,900
1,708
10 mm (0.4 in.)
3,300
1,943
2,350
1,384
20 mm (0.8 in.)
2,800
1,649
1,750
1,031
30 mm (1.2 in.)
2,300
1,355
1,000
589
Compressor Model No.
D3DST-075E-TFD, Semi-hermetic Reciprocating with
Copeland Discus
®
Valve Design
Refrigerant Charge
3.5 Kg (7.7 lb) R-134a
Compressor Oil Capacity
4.6 liter (4.86 qt)*
Compressor Oil Type
Polyol Ester Based Type (required), TK Part No.
203-433**
Typical System Pressures at 37.8 C (100 F) Ambient
Standby (Unit Off, Empty Box):
High Side
—
Low Side
—
-30 C (-22 F) Box, Unit Cooling:
High Side
1500 to 1800 kPa, 15.0 to 18.0 bar, 218 to 261 psig
Low Side
60 to 90 kPa, 0.60 to 0.90 bar, 9 to 13 psig
-60 C (-76 F) Box, Unit Cooling:
High Side
1380 to 1500 kPa, 13.8 to 15.0 bar, 200 to 218 psig
Low Side
20 to 50 kPa, 0.20 to 0.50 bar, 3 to 7 psig
High Pressure Cutout Switch
Cutout
2410 ± 68kPa, 24.10 ± 0.68 bar, 350 ± 10 psig
Cutin
1640 ± 68kPa, 16.4 ± 0.68 bar, 238 ± 10 psig
Fusible Plug (High Pressure Relief)
Relief Temp.
100 C (212 F)
Summary of Contents for Thermo King CRR DF MPC2000
Page 5: ...4 ...
Page 11: ...List of Figures 10 ...
Page 13: ...Introduction 12 ...
Page 19: ...Safety Precautions 18 ...
Page 21: ...Service Guide 20 ...
Page 47: ...Unit Description 46 ...
Page 97: ...Microprocessor Controller 96 ...
Page 101: ...Electrical Maintenance 100 ...
Page 141: ...Structural Accessory Maintenance 140 ...
Page 147: ...Refrigeration System Diagnosis 146 ...
Page 150: ...149 CRR DF MPC2000 Controller Diagram ...
Page 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Page 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Page 153: ...152 CRR DF MP3000A Controller Diagram ...
Page 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Page 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Page 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Page 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Page 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...