DRYER OPTION
32
SSR UP6 15, UP6 20, UP6 25, UP6 30
1. Stop compressor, lock and tag out machine.
DISASSEMBLING THE UNIT
The unit has been designed and constructed to guarantee continuous
operation.
The long service life of some components such as the fan and
compressor depends on good maintenance.
The unit must only be disassembled by a refrigerant specialist.
Refrigerant liquid and lubricating oil inside the refrigeration circuit must
be recovered in compliance with current norms in the country where the
machine is installed.
RECYCLING DISASSEMBLY
Frame and panels
Steel / epoxy resin polyester
Heat exchanger (cooler)
Copper
Pipes
Copper
Drainage system
Polyamide
Heat exchanger insulation
EPS (polystyrene sintered)
Pipe insulation
Gum synthetic
Compressor
Steel / copper / aluminium / oil
Condenser
Steel / copper / aluminium
Refrigerant
R134a
Valve
Brass
Electrical cable
Copper / PVC
REFRIGERANT LEAKS IN THE REFRIGERATION CIRCUIT
The unit is dispatched in perfect working order, already charged.
Refrigerant leaks may be identified by tripping of the compressor
overload protector (SK).
IF A LEAK IS DETECTED IN THE REFRIGERANT CIRCUIT, SEEK
TECHNICAL ASSISTANCE.
REFRIGERANT CHARGING
THIS OPERATION MUST ONLY BE PERFORMED BY A
REFRIGERANT SPECIALIST.
WHEN REPAIRING THE REFRIGERANT CIRCUIT, COLLECT ALL
THE REFRIGERANT IN A CONTAINER AND DISPOSE OF IT IN THE
APPROPRIATE MANNER.
CHARACTERISTICS OF REFRIGERANT R134A
In normal temperature and pressure conditions the above refrigerant is
a colorless, class A1/A1 gas with TVL value of 1000ppm (ASHRAE
classification).
If a refrigerant leak occurs, thoroughly air the room before commencing
work.