OPERATING INSTRUCTIONS (XE SERIES CONTROLLER)
User Interface
The standard user interface configuration of the controller consists of the
membrane and the LCD display. The membrane consists of five command
keys (START, STOP, LOAD, UNLOAD, and RESET), four navigation keys (UP,
RIGHT, LEFT and DOWN), and an Edit mode selection key (ENTER). These keys,
the color graphics display and the LED icons make up the user interface to
the compressor.
Figure 28: Controller Interface
LED status icons
Three LED icons are used to indicate the current status of the control system
from a distance and are located on the upper left side of the user interface.
Table 8: LED Status Icons
Icon
Name Function
OK
Illuminates when no Warnings or Trips are sensed.
Can be in a Ready or Not Ready state.
Alert
Illuminates when an Warning (flashes) or Trip
(constant on) is sensed. Can be in a Ready
(Warning) or Not Ready (Trip) state.
Auto
Illuminates when the compressor stops in auto
restart.
Command keys
These keys command the controller to perform actions as specified in the
following table. When any of these keys are pressed the action below will be
initiated and logged in the event log.
Table 9: Command Keys
Icon
Name Function
---
None
Load
Puts the compressor into the selected mode of
operation. Unit will load if the pressure conditions
are right.
Unload
Puts the compressor into an unloaded state. Unit
will run unloaded.
Icon
Name Function
Reset
Clears Warnings and Trips once the condition is
corrected.
Start
Starts the compressor.
Stop
Stops the compressor. This button should be
pressed instead of the E-Stop for normal stopping
operation.
Enter
Toggles the display between the Navigation mode
and the Edit mode.
NOTICE
The LOAD and UNLOAD keys are not used on variable speed
compressors .
Navigation keys
There are four navigation keys (UP, RIGHT, DOWN and LEFT). While the ENTER
key is not considered a navigation key, it is used in conjunction with the
navigation keys to make or confirm a selection.
Figure 29: Navigation Keys
Pressing one of the navigation keys will lead the user down a navigation path.
Each time the key is pressed, another step in the path is taken. Once the end
of a navigation path is reached, pressing the key one more time will bring the
user back to the beginning of the path. Pressing the opposite key, will move
the user through the navigation path in the opposite direction. Once the
beginning is reached, pressing the opposite key will take the user to the end
of the path.
EN
EN-9
80446339 Rev C
60313.16.03
Summary of Contents for R132-160 kW
Page 32: ...Notes 60313 16 03...
Page 33: ...Notes 60313 16 03...
Page 34: ...Notes 60313 16 03...
Page 36: ...ingersollrandproducts com 2013 Ingersoll Rand plc 60313 16 03...
Page 68: ...Notes 60313 16 03...
Page 69: ...Notes 60313 16 03...
Page 70: ...Notes 60313 16 03...
Page 72: ...ingersollrandproducts com 2013 Ingersoll Rand plc 60313 16 03...
Page 106: ...Notes 60313 16 03...
Page 108: ...ingersollrandproducts com 2013 Ingersoll Rand plc 60313 16 03...
Page 140: ...Notas 60313 16 03...
Page 141: ...Notas 60313 16 03...
Page 142: ...Notas 60313 16 03...
Page 144: ...ingersollrandproducts com 2013 Ingersoll Rand plc 60313 16 03...