SPECIFICATIONS

Model Code Explanation
 

Example: FA2i–24MK320P

 

FA2i

24

M

K

320

P

Series (Capacity):

 

 

 

 

 

 

 

 

 

 

 

 

FA2i =

4,400 lbs (2,000 kg)

Drum Length (Distance between drum flanges):
 

24

=

Standard (Refer to Table 4 ‘Available Drum Lengths’ on page 4.

Drum Brake:

 

A

=

Automatic Drum Brake

M

=

Manual Drum Brake

X

=

None

Disc Brake:

 

K

=

Automatic Disc Brake

 

X

=

None

Control:
 

1

=

Winch mounted lever throttle (Standard)

 

*

2XX

=

Remote full flow lever throttle [XX = Specify hose length (feet). Maximum 20 ft. (6 metres)]  

*

3XX

=

Remote pilot pendant throttle [XX = Specify hose length (feet). Maximum 66 ft. (20 metres)]***

*

4XX

=

Remote pilot lever throttle [XX = Specify length (feet). Maximum 66 ft. (20 metres)]***

*

5XX

=

Remote electric over air throttle †***

Options: **
 

7

=

Drum Grooving (Number = wire rope size in sixteenths, e.g. 7/16 inch) †

 

B

=

Extended Warranty

 

**

CM

=

Low Temperature Components; (C1M3 = -20° ABS), (C2M3 = -20° DNV)

 

D

=

Drum Divider Flange and additional wire rope anchor †

 

E

=

Construction Cage †

 

G

=

Drum Guard

 

J

=

Air Line Accessories (not mounted to winch)

 

 

L

=

Drum Locking Pin

**

M1

=

Material Traceability (typical material results) ††

**

M2

=

Material Traceability (actual material results) ††

**

M3

=

Material Traceability (actual material results for these parts in finished, as-delivered condition) ††

 

N4

=

Manufactured under American Bureau of Shipping (ABS) Survey

 

N5

=

Manufactured under Det Norske Veritas (DNV) Survey

 

P

=

Marine 812 Grade Corrosion Preventative Finish

 

P1

=

Marine 812-X Grade Corrosion Preventative Finish

 

 

Q

=

Adjustable Accu-Spool™ †

W1

= ABS witness test

 

R

=

Slack Wire Rope Detector

W2

= DNV witness test

 

S

=

Limit Switch (upper and lower)

W3

= LRS witness test

 

U

=

Underwound (wire rope operation)

W4

= Customer witness test

 

V

=

Press Roller

X

= Testing; please specify

 

-CE

= Compliance with European Machinery Directive and EN14492–1

Y

= Overload protection and emergency stop on lever

throttle

Notes:

*

Remote throttles are provided with 6 feet (2 metres) of hose. Specify hose lengths greater than 6 feet. For lengths greater than 20 feet (6 metres) with the Remote
Full Flow Throttle, or 66 feet (20 metres) with the Remote Pilot Lever and Remote Pilot Pendant Throttles contact your Ingersoll Rand distributor or the factory

for control acceptability. Metric lengths are provided for reference only, order lengths in feet. (Used with Disc and Auto Band Brake only.)

**

Documentation, witness testing and material traceability available; must be requested at time of order. Specify options or contact the factory or your nearest

Ingersoll Rand distributor for information.

***

Not available with -CE option, or units equipped with limit switches.

Not covered in this manual.

††

Refer to ‘Traceability’ on page 4 for a description of the differences between M1, M2 and M3.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All -E models are manufactured to previous European Machinery directives. Refer to Data (Name) Plate on winch to determine model. If winch is a custom build also refer

to the Declaration of Conformity for serial number break.

Form MHD56436 Edition 7

3

Summary of Contents for FA2i

Page 1: ...Product Information FORCE 5i Air Winch Models FA2i and FA2i CE CE Compliant With European Directives Save These Instructions R Form MHD56436 Edition 7 February 2016 45899788 2016 Ingersoll Rand...

Page 2: ...and shaft to the planetary reduction gear assembly Output from the planetary reduction gear assembly is connected to the wire rope drum through the output shaft The disc brake assembly consisting of...

Page 3: ...ive Finish P1 Marine 812 X Grade Corrosion Preventative Finish Q Adjustable Accu Spool W1 ABS witness test R Slack Wire Rope Detector W2 DNV witness test S Limit Switch upper and lower W3 LRS witness...

Page 4: ...ic inspection and testing i e results are actual material properties for these parts in a finished as delivered condition ComponentswithpartnumbersendinginCHarecharpypartsforuseunderextreme cold condi...

Page 5: ...re rope manufacturer s recommendation on use and maintenance of wire rope n Wire Rope Spooling To compensate for uneven spooling and the decrease in line pull capacity as the drum fills up use as shor...

Page 6: ...erationpriortoleavingthefactory Beforethewinch is placed into service the following initial operating checks should be performed 1 When first running the motor inject a small amount of light oil into...

Page 7: ...calibrated to 160 of winch rated capacity Shift control lever to haul in position 1 If overload valve activates reset overload valve Winch is ready for normal operation 2 If winch lifts higher than 16...

Page 8: ...on of wire rope such as kinking birdcaging core protrusion main strand displacement corrosion brokenorcutstrands Ifdamageisevident donotoperatewinchuntil the discrepancies have been reviewed and inspe...

Page 9: ...res 3 8 0 35 n Reduction Gear Assembly Refer to Dwg MHP0140 on page 12 A Fill Plug Position B Drum C Reduction Gear Assembly D Inboard Upright E Level Plug Position The reduction gear is filled to the...

Page 10: ...S A B A B B C DRUM Dwg MHP0133 Dwg MHP2686 Payout Haul In A D Lift Slider Handle UP to Unlock C Dwg MHP3099 Air Out Regulator Lubricator Air In Filter A B C D E Dwg MHP0191 TOP Dwg MHP2772 Dwg MHP2688...

Page 11: ...8 Push In Turn in a counterclockwise direction to reset Emergency Stop A B Dwg MHP2557 Twist Red Button to Reset A Dwg MHP2558 Dwg MHP1348 Emergency Stop Button ON Button Function Levers Pendant Handl...

Page 12: ...ORMATION GRAPHICS CONTINUED Level Plug Fill Plug Drain Plug C A B Dwg MHP0222 A B C E D Fill Plug Position Drum Reduction Gear Assembly Level Plug Position Inboard Upright Dwg MHP0140 12 Form MHD56436...

Page 13: ...SERVICE NOTES Form MHD56436 Edition 7 13...

Page 14: ...SERVICE NOTES 14 Form MHD56436 Edition 7...

Page 15: ...n ch siel SL Model Obmo je serijskih tevilk SV Modell Serienummer mellan To which this declaration relates is in compliance with provisions of Directive s 2006 42 EC machinery 2014 34 EU ATEX CS Ke kt...

Page 16: ...R ingersollrandproducts com...

Reviews: