27
Modulate Control Valve Adjustment
Ensure the compressor is isolated from the
compressed air system by closing the isolation
valve and venting pressure from the drip leg.
Ensure the main power disconnect switch is
locked open and tagged.
1. Enter the setpoint routine and put the compressor
in the MODULATION mode. Refer to Section 3.5 for
instructions.
2. Remove 1/8" NPT plug from the tee in the control
piping on the side of the airend support. Connect a
pressure gauge to this port.
3. Loosen the adjustment screw locknut and back
out adjusting screw 3 turns. See Figure 4.7-2.
4. Open the isolation valve and start the compressor.
5. Adjust the isolation valve to bring the discharge
air pressure to the rated discharge pressure (125,
140, or 200 psig).
6. While MAINTAINING the rated discharge
pressure, turn the adjustment screw on the
modulation valve (see Figure 4.7-2) so that the test
pressure gauge reads:
22 psig for modulate 60% cfm (full voltage units)
16 psig for modulate 60% cfm (star-delta units)
20 psig for modulate 70% cfm (full voltage units)
18 psig for modulate 70% cfm (star-delta units)
Tighten the adjustment screw locknut.
7. Press UNLOADED STOP. Wait for sump pressure
to go 0 psig. Close the isolation valve or bleed off all
system air.
8. Enter the setpoint routine and put the compressor
in the desired control mode.
9. Remove the test pressure gauge and replace the
1/8" NPT plug using Loctite
®
PST or similar thread
sealant.
*Loctite is a registered trademark.
FIGURE 4.7-2 MODULATION VALVE
WARNING
!
Hazardous voltage. Can cause
severe injury or death.
Disconnect power before servicing.
Lockout/Tagout machine.
INGERSOLLrAND
®
WARNING
!
High pressure air.
Can cause severe injury or death.
Relieve pressure before removing filter
plugs / caps, fittings or covers.
INGERSOLLrAND
®
LOCKNUT
ADJUSTING SCREW
Summary of Contents for EP 20 SE
Page 18: ...16 FIGURE 2 5 1 TYPICAL OUTDOOR SHELTERED INSTALLATION ...
Page 48: ...46 8 0 REFERENCE DRAWINGS 8 1 ELECTRICAL SCHEMATIC FULL VOLTAGE 39838388 REV 01 ...
Page 49: ...47 8 2 ELECTRICAL SCHEMATIC STAR DELTA 39851985 REV 01 ...
Page 50: ...48 8 3 ELECTRICAL SCHEMATIC FULL VOLTAGE REMOTE MOUNTED STARTER 39845029 REV 01 ...
Page 51: ...49 NOTES ...
Page 52: ...50 8 4 FOUNDATION PLAN ENCLOSED Continued 39838750 REV 02 ...
Page 53: ...51 8 4 FOUNDATION PLAN ENCLOSED 39838750 REV 02 ...
Page 54: ...52 8 4 FOUNDATION PLAN UNENCLOSED Continued 39848171 REV 02 ...
Page 55: ...53 8 4 FOUNDATION PLAN UNENCLOSED 39848171 REV 02 ...
Page 56: ...54 8 6 FOUNDATION PLAN OUTDOOR MODIFICATION Continued 39848189 REV 02 ...
Page 57: ...55 8 6 FOUNDATION PLAN OUTDOOR MODIFICATION 39848189 REV 02 ...
Page 62: ...60 8 11 TYPICAL SYSTEM FLOW DIAGRAMS TYPICAL SYSTEM FLOW DIAGRAM ...
Page 63: ...61 8 11 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 64: ...62 8 11 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 65: ...63 8 11 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 66: ...64 8 11 TYPICAL SYSTEM FLOW DIAGRAMS ...
Page 67: ...65 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY 9 0 MAINTENANCE RECORD ...
Page 68: ...66 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...
Page 69: ...67 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...
Page 70: ...68 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...