CENTAC TROUBLESHOOTING GUIDE
17
CST-TP0007
1994 Ingersoll-Rand Company
Date of issue: January, 1999 Supersedes: 16-dec-94
in
mm
/ sec.
/ sec.
.
=
×
0 03937
mm
in
/ sec.
/ sec.
.
=
×
25 40
total vibration(in mils) = 1 25
12000
.
×
RPM
8.
Water Quality Requirements
Total hardness (expressed as CaCo
3
)
less than 100 PPM
Suspended solids
less than 50 PPM
Maximum water temperature (cooler discharge)
140°F/60°C
pH range
6.0 - 8.5
Langlier saturation index (LI)
+0.5 - +1.0
A low pH level promotes corrosion and high levels of dissolved oxygen.
A high pH level increases the chance of scale formation.
A low LI indicates the water tends to be corrosive.
A high LI indicates a tendency to form scale.
It is recommended to contact a reputable water treatment professional if there are questions
regarding water quality.
Rev. C
24 Mar. 1995
AVERAGE
RMS
PEAK TO PEAK
PEAK
0
+
-
0.707
0.637