background image

OPERATOR’S MANUAL 

RM072S-XXX-XX

INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE.

INCLUDE MANUALS: S-635 General Information (pn 97999-635).

RELEASED: 12-14-12

REVISED: 10-27-17

(REV: D)

RM072S-XXX-XX

TWO POST LIFT / RAM

For use with 16 gallon / 60 liter drums (tapered or straight)

INGERSOLL RAND COMPANY LTD

209 NORTH MAIN STREET – BRYAN, OHIO 43506

 (800) 495-0276 

 FAX (800) 892-6276 

© 2017 

CCN 46763785

arozone.com

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

SERVICE KITS

 

y

Use only genuine ARO® replacement parts to assure compatible 

pressure rating and longest service life.

 

y

104217

 for repair of P39124-120 filter / regulator.

 

y

104453

 for repair of P39344-110 filter / regulator.

 

y

637466

 for repair of lift / ram seals.

SPECIFICATIONS

Model Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .  RM072S-XXX-XX

Maximum Working Pressure . . . . . . . . . . . . .   125 psig (8.6 bar)

Maximum Temperature Limits  . . . . . . . . . . .   10º F to 180º F (-12º C to 

82º C)

Base Dimensions . . . . . . . . . . . . . . . . . . . . . . . .   19-3/4” x 24” (501.7 mm 

x 609.6 mm)

Height (lowered) . . . . . . . . . . . . . . . . . . . . . . . .   43-37/64” (1106.6 mm)

(raised)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   73-27/64” (1864.8 mm)

Stroke  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   29-55/64” (758.2 mm)

Weight   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   160 lbs (71.5 kgs)

Noise Level @ 125 psig (continuous duty)   82.4 dB(A)

 The pump sound pressure levels published here have been updated to 

an Equivalent Continuous Sound Level (LA

eq

) to meet the intent of ANSI 

S1.13-1971, CAGI-PNEUROP S5.1 using four microphone locations.

GENERAL DESCRIPTION

The ARO model RM072S-XXX-XX two post lift / ram uses two 3-1/4” 

air powered cylinders connected by a steel cross member and 

welded to a heavy gauge base plate. It is normally used to raise and 

lower a fluid handling pump and follower in and out of a standard 

16 gallon / 60 liter drum, or when used as a ram, it can force high 

viscosity flowable material into the pump inlet.

When properly secured (see “General Information - Air Operated 

Lifts and Rams”), this unit has the ability to raise a pump to clear a 

standard 16 gallon / 60 liter drum. The operator is then able to eas-

ily remove the pump from the drum.

This lift / ram uses a rotary 3-way control valve which controls the 

air necessary to raise and lower the lift / ram. This unit includes 

an auxiliary manual air valve which is used to supply a controlled 

amount of air pressure to the bottom of the follower plate. When 

the control valve is in the  “up” position, a small amount of air pres-

sure applied under the follower plate will help raise the follower 

plate, pump and lift / ram by relieving the vacuum (see page 3).

IMPORTANT

This is one of four documents which support the system. Re-

placement copies of these forms are available upon request.

  RM072S-XXX-XX Model Operator’s Manual (pn 97999-1707)

  S-635 General Information - Air Operated Lifts and Rams (pn 

97999-635)

  P391XX-XXX Piggyback Filter / Regulator Operator's Manual (pn 

100400-59)

  P393XX-XXX Piggyback Filter / Regulator Operator's Manual (pn 

100400-69

RM072S-XXX-XX Two Post Lift / Ram

Figure 1

Summary of Contents for ARO RM072S Series

Page 1: ...71 CAGI PNEUROP S5 1 using four microphone locations GENERAL DESCRIPTION The ARO model RM072S XXX XX two post lift ram uses two 3 1 4 air powered cylinders connected by a steel cross member and welded...

Page 2: ...7 tie rod D 16 gallon Container 18 507 tie rod E 16 gallon Container 8 007 tie rod A Standard Footprint C Slip On D Pipe Thread A Aluminium E Carbon Steel Electroless Nickel Coating C Stainless Steel...

Page 3: ...at higher pressure may cause lift damage and or personal injury and or property damage Do not service or clean pump hoses or dispensing valve while the system is pres surized WARNING DO NOT EXCEED DR...

Page 4: ...curing type compounds from bonding to the seal 7 Check the vent plug on the follower plate to be sure it easily threads in and out It is recommended to lubricate the threads of the plug to help preve...

Page 5: ...9850 51 Lock OutValve 1 2 14 NPT 1 104392 4 52 Nipple 1 4 18 NPT x 7 8 1 Y27 12 C 53 Tubing 5 16 o d x 11 1 94980 54 T TypeWall Mount 2 104401 55 Button Head Screw M10 x 1 5 6g x 18 mm 1 96696 56 Bulk...

Page 6: ...A View B NOTE DO NOT OVERTIGHTEN FASTENERS 1 nut 75 ft lbs 101 7 Nm Lubricate all O rings U cups and mating parts with Gadus S2 U1000 grease 4 25 24 4 3 6 5 2 1 1 2 18 8 23 7 9 see view B see view A...

Page 7: ...on head screw 20 ft lbs 27 1 Nm 49 cap screw 95 100 in lbs 10 7 11 3 Nm 54 screw 17 in lbs 1 9 Nm 55 button head screw 20 ft lbs 27 1 Nm ASSEMBLY TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS...

Page 8: ...Page 8 of 12 RM072S XXX XX en PARTS LIST RM072S XXX XX 40 58 16 36 14 47 48 52 33 13 50 54 51 32 57 55 43 34 42 12 30 15 26 10 15 44 32 19 20 15 41 Figure 5...

Page 9: ...gle Lip Nitrile Polyethylene 11 614 295 0 mm 67486 2 RM072S XXC E3 Polyurethane Polyethylene 11 437 290 5 mm 67486 1 RM072S XXC E5 Nitrile Polyethylene 12 281 311 9 mm 67486 3 RM072S XXC E4 Polyuretha...

Page 10: ...62 mm 242 mm OPTIONS CONFIGURATION Available on the following models 67485 X 67486 X 67487 X 67518 X Ideal for tapered pails Ideal for various straight sided pails Ideal for various straight sided pai...

Page 11: ...RM072S XXX XX en Page 11 of 12 DIMENSIONAL DATA 22 000 24 000 1 000 28 223 24 884 for RM072S C only 16 750 0 562 4 PLACES 1 500 19 750 16 375 43 568 29 85 TRAVEL Figure 8...

Page 12: ...Page 12 of 12 RM072S XXX XX en PN 97999 1707 NOTES...

Reviews: